Fail to get disk vender Lexar SSD NM620 1TB
burianvlastimil opened this issue · 4 comments
Hello, I have bought new Lexar NVMe drives and want to set them up as RAID1 storage.
But I received the error Fail to get disk vender Lexar SSD NM620 1TB.
Is this something I should care about or not? The process of creating the pool seems to be functioning.
However, I have doubts if I later run the https://github.com/007revad/Synology_HDD_db script, whether it will work?
Thanks and cheers.
The https://github.com/007revad/Synology_HDD_db script will fix the unknown vendor issue (which causes an Unknown firmware version error in Storage Manager).
If your Synology has a Ryzen, Intel Celeron J4025 or J4125, or Realtek RTD1619B CPU you won't even need Synology_M2_Volume as after running Synology_HDD_db you will be able to create the storage pool and volume in Storage Manager.
I admit, I am unsure how you mean it now. I meant after DSM upgrade, which will happen sooner or later, I am instructed by your script to run the db
script. Should I do it now? My NAS basic details:
https://www.synology.com/en-us/products/DS923+#specs
Screens:
After running your db
script and rebooting, it is showing HS/MAXIO --> what is that pls?
You can change it to Lexar with:
sudo synosetkeyvalue /usr/syno/etc.defaults/pci_vendor_ids.conf 0x05dc Lexar
sudo synosetkeyvalue /usr/syno/etc/pci_vendor_ids.conf 0x05dc Lexar