Storage pool not appears after format
SeeYouDown opened this issue · 7 comments
SSD NVMe type intel U.2 INTEL SSDPE2KX010T8
after completing this step
mdadm: Defaulting to version 1.2 metadata
mdadm: array /dev/md5 started.
Creating a physical volume (PV) on md5 partition
Really INITIALIZE physical volume "/dev/md5" of volume group "vg5" [y/n]? y
WARNING: Forcing physical volume creation on /dev/md5 of volume group "vg5"
Physical volume "/dev/md5" successfully created
Creating a volume group (VG) on md5 partition
Volume group "vg5" successfully created
M.2 volume support already enabled.
Steps you need to do after running this script:
- After the restart go to Storage Manager and select online assemble:
Storage Pool > Available Pool > Online Assemble - Create the volume as you normally would:
Select the new Storage Pool > Create > Create Volume - Optionally enable TRIM:
Storage Pool > ... > Settings > SSD TRIM
SSD TRIM option is only available in DSM 7.2 Beta for RAID 1
Nothing shows up
Nas model : 1621+
output of : udevadm info /dev/nvme0n1
P: /devices/pci0000:00/0000:00:01.2/0000:07:00.0/nvme/nvme0/nvme0n1
N: nvme0n1
E: DEVNAME=/dev/nvme0n1
E: DEVPATH=/devices/pci0000:00/0000:00:01.2/0000:07:00.0/nvme/nvme0/nvme0n1
E: DEVTYPE=disk
E: MAJOR=259
E: MINOR=0
E: PHYSDEVBUS=pci
E: PHYSDEVDRIVER=nvme
E: PHYSDEVPATH=/devices/pci0000:00/0000:00:01.2/0000:07:00.0
E: SUBSYSTEM=block
E: SYNO_ATTR_SERIAL=PHLJ245400A41P0FGN
E: SYNO_DEV_DISKPORTTYPE=UNKNOWN
E: SYNO_INFO_PLATFORM_NAME=v1000
E: SYNO_KERNEL_VERSION=4.4
E: SYNO_SUPPORT_USB_PRINTER=yes
E: SYNO_SUPPORT_XA=no
E: TAGS=:systemd:
E: USEC_INITIALIZED=643293
What does the following return?
synonvme --m2-card-model-get /dev/nvme0n1
I doubt any M.2 PCIe card that is not a Synology M2D20, M2D18, M2D17 or E10M20-T1 will work in DSM.
I can make the DS1621+ work with a Synology M2D20, M2D18, M2D17 or E10M20-T1. See https://github.com/007revad/Synology_enable_M2_card
Thanks for the usual support
synonvme --m2-card-model-get /dev/nvme0n1
Not M.2 adapter card
Unfortunately if DSM isn't seeing the PCIe card with synonvme the drive won't show up in storage manager.
That card is very cheap. I might buy one myself to see if I can get it working in my DS1821+
The card working on my proxmox server out of the box, the good thing with U.2 storage they are last Very LOOONG
Unfortunately if DSM isn't seeing the PCIe card with synonvme the drive won't show up in storage manager.
That card is very cheap. I might buy one myself to see if I can get it working in my DS1821+
Is it possible to enable it? create RAID5 without official M.2 NVMe adapter card.