MIB 257 Equipment ID encoding
Gruni22 opened this issue · 4 comments
Hi,
first of all, I want to thank you for all your effort!!!
I have the DFP-34X-2C2 GPON Stick and managed to get it on ONU State O3 with cloning data.
In the past I already managed to get the FS.com GPON and ZTE F6005 working.
The FS.com cannot sync with 2,5 Gbit because my SFP+ Card does not bring it up.
The ZTE F6005 is a nice solution, but it's not SFP ;-)
Now my issue:
No matter which firmware I try, they seem to have problems of proper HEX Encoding of MIB 257 data.
What I need is exactly that (same output from working devices) (shortened output):
`EqtID = 5f 5f 5f 5f 5f 5f 5f 5f 5f 5f 47 2d 30 31 30 47 2d 51 5f 5f
OMCCVer = 160
NumOfPriQ = 33
NumOfScheduler = 9
NumOfGemPort = 33
QosCfgFlexibility = 1`
What I get is with DFP-34X-2C2 that (shortened output):
`EqtID : _________G-010G-Q # should be Hex encoded
OMCCVer : 0xa0 #HEX for 160 - should be OK
NumOfPriQ : 128 # No Idea how to change or relevant
NumOfScheduler : 9 # No Idea how to change or relevant
NumOfGemPort : 64 # No Idea how to change or relevant
QosCfgFlexibility : 0x003b # No Idea how to change or relevant`
Do you have any idea how to change those values?
Kind Regards,
Matthias
if you query from omcicli mib get <id>
most the value is Decimal by default, when in Hex, always start with 0x
maybe you can try omcicli mib set 257 OMCCVer 0xa0
see what happen
syntax: omcicli mib set <mib_id> <instance_name> <value>
Thanks for response!
If I enter:
omcicli mib set 257 0x0000 EqtID G-010G-Q
I receive:
EqtID: 0x472d303130472d51000000000000000000000000
If I enter:
omcicli mib set 257 0x0000 EqtID 0x5f5f5f5f5f5f5f5f5f5f472d303130472d515f5f
I receive:
EqtID: 0x5f5f5f5f5f5f5f5f5f5�
omcicli mib set 257 0x0000 EqtID __________G-010G-Q_
EqtID: 0x5f5f5f5f5f5f5f5f5f5f472d303130472d515f00
omcicli mib set 257 0x0000 EqtID __________G-010G-Q__
EqtID: __________G-010G-Q__
Did also the test with:
omcicli mib set 257 0x0000 OMCCVer 0xa0
omcicli mib set 257 0x0000 OMCCVer 0xaa
Where both values are interpreted correctly.
Thanks for response! If I enter:
omcicli mib set 257 0x0000 EqtID G-010G-Q
I receive:EqtID: 0x472d303130472d51000000000000000000000000
If I enter:
omcicli mib set 257 0x0000 EqtID 0x5f5f5f5f5f5f5f5f5f5f472d303130472d515f5f
I receive:EqtID: 0x5f5f5f5f5f5f5f5f5f5�
omcicli mib set 257 0x0000 EqtID __________G-010G-Q_
EqtID: 0x5f5f5f5f5f5f5f5f5f5f472d303130472d515f00
omcicli mib set 257 0x0000 EqtID __________G-010G-Q__
EqtID: __________G-010G-Q__
Did also the test with:
omcicli mib set 257 0x0000 OMCCVer 0xa0
omcicli mib set 257 0x0000 OMCCVer 0xaa
Where both values are interpreted correctly.
Did you find a solution?
No.
Ich contacted the supplier for a firmware update.
They said it should work, but it does not.