Anime4000/RTL960x

Can't get O5 state on ODI stick

d-kononov opened this issue · 1 comments

Provider uses BDCOM.
I have telnet access to the provider's ONU.
I tried to set/clone all the values with using ODI's web interface...

Provider's ONU:

# flash get GPON_PLOAM_PASSWD
GPON_PLOAM_PASSWD=1234567890

I tried to set PLOAM password with using ODI's web interface and it returns:

# flash get GPON_PLOAM_PASSWD
GPON_PLOAM_PASSWD=31323334353637383930

Not sure if that is correct, seems like it adds 3 to each symbol. But ONU state is 3. I tried to set it using telnet:

# flash set GPON_PLOAM_PASSWD 1234567890
GPON_PLOAM_PASSWD=1234567890

No luck...
So I'm not sure what is the correct value for PLOAM_PASSWORD, should I use hex or ASCII or add 0 to each symbol... or maybe OLT wan't to get something else from me...

BTW logs from OLT:

May 21 17:26:39 %GPON-ONUACTIVATE: ONU RTKG:11111111 is activated on GPON0/4:2.
May 21 17:26:38 %GPON-ONUDISCOVER: ONU RTKG:11111111 is discovered on GPON0/4:2.
May 21 17:26:36 %GPON-ONUDEACTIVATE: ONU RTKG:11111111 is deactivated on GPON0/4:2, cause Omci linkdown.

I guess I need to fix some other values, but not sure what values should be changed.
Could anyone please help me?

Fixed by running:

# flash set GPON_PLOAM_FORMAT 0
GPON_PLOAM_FORMAT=0
# flash set GPON_PLOAM_PASSWD 1234567890
GPON_PLOAM_PASSWD=1234567890