Channel CV Calibration / In Range resetting each other
cowboy opened this issue · 3 comments
I'm on fw v1.0.1, and I've noticed the following issues:
- When I calibrate a Channel CV it resets the In Range to +10
- When I change a Channel In Range to +5 it resets the CV calibration
(I have only tried this with Channel 1/2 CV)
To start, these are the settings I need for my MIDI device, so I do:
- Channel 1
- CV
- Function → CC → 004
- MIDI Channel → 16
- Ranges
- In Range → +5
- CV
And this is what I see on the screen when I supply a voltage:
- Input 0V → CV 0
- Input 5V → CV 112
So, I calibrate using a reliable voltage source:
- Channel 1
- Ranges
- Calibration
- Set 1V with 1V source (showed 0.91V before calibration, now shows 1V)
- Set 4V with 4V source (showed 6.86V before calibration, now shows 4V)
- Calibration
- Ranges
This is what I expect to see:
- Input 0V → CV 0
- Input 5V → CV 127
But this is what I actually see:
- Input 0V → CV 0
- Input 5V → CV 63
- Input 10V → CV 127
It appears that calibrating has reset In Range to +10, so I set it to +5:
- Channel 1
- Ranges
- In Range → +5
- Ranges
And now I see the pre-calibration values again:
- Input 0V → CV 0
- Input 5V → CV 112
So, I go back to the calibration screen, and see the pre-calibration voltages:
- Channel 1
- Ranges
- Calibration
- 1V source shows 0.91V again
- 4V source shows 6.86V again
- Calibration
- Ranges
I'm happy to beta test any fix, just LMK
Managed to reproduce this issue. It is a bug that will be solved in version 1.1
Please contact us via mail and request 16 May Beta version to test.
Fixed in current version!