Designate a canonical class in each set of equivalent classes

ektrah opened this issue ยท 10 comments

Brick currently contains a number of classes that are equivalent to each other, such as brick:AED and brick:Automated_External_Defibrillator, or brick:AHU, brick:Air_Handler_Unit, and brick:Air_Handling_Unit.

Details (click to expand)
Class Equivalent Class
AED AED
AED Automated_External_Defibrillator
AHU AHU
AHU Air_Handler_Unit
AHU Air_Handling_Unit
Air_Handler_Unit AHU
Air_Handler_Unit Air_Handler_Unit
Air_Handler_Unit Air_Handling_Unit
Air_Handling_Unit AHU
Air_Handling_Unit Air_Handler_Unit
Air_Handling_Unit Air_Handling_Unit
Automated_External_Defibrillator AED
Automated_External_Defibrillator Automated_External_Defibrillator
Average_Discharge_Air_Flow_Sensor Average_Discharge_Air_Flow_Sensor
Average_Discharge_Air_Flow_Sensor Average_Supply_Air_Flow_Sensor
Average_Supply_Air_Flow_Sensor Average_Discharge_Air_Flow_Sensor
Average_Supply_Air_Flow_Sensor Average_Supply_Air_Flow_Sensor
Break_Room Break_Room
Break_Room Breakroom
Breakroom Break_Room
Breakroom Breakroom
CAV CAV
CAV Constant_Air_Volume_Box
Computer_Room_Air_Conditioning Computer_Room_Air_Conditioning
Computer_Room_Air_Conditioning CRAC
Computer_Room_Air_Handler Computer_Room_Air_Handler
Computer_Room_Air_Handler CRAH
Constant_Air_Volume_Box CAV
Constant_Air_Volume_Box Constant_Air_Volume_Box
Cooling_Discharge_Air_Flow_Setpoint Cooling_Discharge_Air_Flow_Setpoint
Cooling_Discharge_Air_Flow_Setpoint Cooling_Supply_Air_Flow_Setpoint
Cooling_Discharge_Air_Temperature_Deadband_Setpoint Cooling_Discharge_Air_Temperature_Deadband_Setpoint
Cooling_Discharge_Air_Temperature_Deadband_Setpoint Cooling_Supply_Air_Temperature_Deadband_Setpoint
Cooling_Discharge_Air_Temperature_Integral_Time_Parameter Cooling_Discharge_Air_Temperature_Integral_Time_Parameter
Cooling_Discharge_Air_Temperature_Integral_Time_Parameter Cooling_Supply_Air_Temperature_Integral_Time_Parameter
Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter
Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter Cooling_Supply_Air_Temperature_Proportional_Band_Parameter
Cooling_Supply_Air_Flow_Setpoint Cooling_Discharge_Air_Flow_Setpoint
Cooling_Supply_Air_Flow_Setpoint Cooling_Supply_Air_Flow_Setpoint
Cooling_Supply_Air_Temperature_Deadband_Setpoint Cooling_Discharge_Air_Temperature_Deadband_Setpoint
Cooling_Supply_Air_Temperature_Deadband_Setpoint Cooling_Supply_Air_Temperature_Deadband_Setpoint
Cooling_Supply_Air_Temperature_Integral_Time_Parameter Cooling_Discharge_Air_Temperature_Integral_Time_Parameter
Cooling_Supply_Air_Temperature_Integral_Time_Parameter Cooling_Supply_Air_Temperature_Integral_Time_Parameter
Cooling_Supply_Air_Temperature_Proportional_Band_Parameter Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter
Cooling_Supply_Air_Temperature_Proportional_Band_Parameter Cooling_Supply_Air_Temperature_Proportional_Band_Parameter
CRAC Computer_Room_Air_Conditioning
CRAC CRAC
CRAH Computer_Room_Air_Handler
CRAH CRAH
DDAHU DDAHU
DDAHU Dual_Duct_Air_Handling_Unit
Dedicated_Outdoor_Air_System_Unit Dedicated_Outdoor_Air_System_Unit
Dedicated_Outdoor_Air_System_Unit DOAS
Discharge_Air Discharge_Air
Discharge_Air Supply_Air
Discharge_Air_Dewpoint_Sensor Discharge_Air_Dewpoint_Sensor
Discharge_Air_Dewpoint_Sensor Supply_Air_Dewpoint_Sensor
Discharge_Air_Differential_Pressure_Sensor Discharge_Air_Differential_Pressure_Sensor
Discharge_Air_Differential_Pressure_Sensor Supply_Air_Differential_Pressure_Sensor
Discharge_Air_Differential_Pressure_Setpoint Discharge_Air_Differential_Pressure_Setpoint
Discharge_Air_Differential_Pressure_Setpoint Supply_Air_Differential_Pressure_Setpoint
Discharge_Air_Duct_Pressure_Status Discharge_Air_Duct_Pressure_Status
Discharge_Air_Duct_Pressure_Status Supply_Air_Duct_Pressure_Status
Discharge_Air_Flow_Demand_Setpoint Discharge_Air_Flow_Demand_Setpoint
Discharge_Air_Flow_Demand_Setpoint Supply_Air_Flow_Demand_Setpoint
Discharge_Air_Flow_High_Reset_Setpoint Discharge_Air_Flow_High_Reset_Setpoint
Discharge_Air_Flow_High_Reset_Setpoint Supply_Air_Flow_High_Reset_Setpoint
Discharge_Air_Flow_Low_Reset_Setpoint Discharge_Air_Flow_Low_Reset_Setpoint
Discharge_Air_Flow_Low_Reset_Setpoint Supply_Air_Flow_Low_Reset_Setpoint
Discharge_Air_Flow_Reset_Setpoint Discharge_Air_Flow_Reset_Setpoint
Discharge_Air_Flow_Reset_Setpoint Supply_Air_Flow_Reset_Setpoint
Discharge_Air_Flow_Sensor Discharge_Air_Flow_Sensor
Discharge_Air_Flow_Sensor Supply_Air_Flow_Sensor
Discharge_Air_Flow_Setpoint Discharge_Air_Flow_Setpoint
Discharge_Air_Flow_Setpoint Supply_Air_Flow_Setpoint
Discharge_Air_Humidity_Sensor Discharge_Air_Humidity_Sensor
Discharge_Air_Humidity_Sensor Supply_Air_Humidity_Sensor
Discharge_Air_Humidity_Setpoint Discharge_Air_Humidity_Setpoint
Discharge_Air_Humidity_Setpoint Supply_Air_Humidity_Setpoint
Discharge_Air_Integral_Gain_Parameter Discharge_Air_Integral_Gain_Parameter
Discharge_Air_Integral_Gain_Parameter Supply_Air_Integral_Gain_Parameter
Discharge_Air_Plenum Discharge_Air_Plenum
Discharge_Air_Plenum Supply_Air_Plenum
Discharge_Air_Proportional_Gain_Parameter Discharge_Air_Proportional_Gain_Parameter
Discharge_Air_Proportional_Gain_Parameter Supply_Air_Proportional_Gain_Parameter
Discharge_Air_Smoke_Detection_Alarm Discharge_Air_Smoke_Detection_Alarm
Discharge_Air_Smoke_Detection_Alarm Supply_Air_Smoke_Detection_Alarm
Discharge_Air_Static_Pressure_Deadband_Setpoint Discharge_Air_Static_Pressure_Deadband_Setpoint
Discharge_Air_Static_Pressure_Deadband_Setpoint Supply_Air_Static_Pressure_Deadband_Setpoint
Discharge_Air_Static_Pressure_Integral_Time_Parameter Discharge_Air_Static_Pressure_Integral_Time_Parameter
Discharge_Air_Static_Pressure_Integral_Time_Parameter Supply_Air_Static_Pressure_Integral_Time_Parameter
Discharge_Air_Static_Pressure_Proportional_Band_Parameter Discharge_Air_Static_Pressure_Proportional_Band_Parameter
Discharge_Air_Static_Pressure_Proportional_Band_Parameter Supply_Air_Static_Pressure_Proportional_Band_Parameter
Discharge_Air_Static_Pressure_Sensor Discharge_Air_Static_Pressure_Sensor
Discharge_Air_Static_Pressure_Sensor Supply_Air_Static_Pressure_Sensor
Discharge_Air_Static_Pressure_Setpoint Discharge_Air_Static_Pressure_Setpoint
Discharge_Air_Static_Pressure_Setpoint Supply_Air_Static_Pressure_Setpoint
Discharge_Air_Static_Pressure_Step_Parameter Discharge_Air_Static_Pressure_Step_Parameter
Discharge_Air_Static_Pressure_Step_Parameter Supply_Air_Static_Pressure_Step_Parameter
Discharge_Air_Temperature_Alarm Discharge_Air_Temperature_Alarm
Discharge_Air_Temperature_Alarm Supply_Air_Temperature_Alarm
Discharge_Air_Temperature_Cooling_Setpoint Discharge_Air_Temperature_Cooling_Setpoint
Discharge_Air_Temperature_Cooling_Setpoint Supply_Air_Temperature_Cooling_Setpoint
Discharge_Air_Temperature_Deadband_Setpoint Discharge_Air_Temperature_Deadband_Setpoint
Discharge_Air_Temperature_Deadband_Setpoint Supply_Air_Temperature_Deadband_Setpoint
Discharge_Air_Temperature_Heating_Setpoint Discharge_Air_Temperature_Heating_Setpoint
Discharge_Air_Temperature_Heating_Setpoint Supply_Air_Temperature_Heating_Setpoint
Discharge_Air_Temperature_High_Reset_Setpoint Discharge_Air_Temperature_High_Reset_Setpoint
Discharge_Air_Temperature_High_Reset_Setpoint Supply_Air_Temperature_High_Reset_Setpoint
Discharge_Air_Temperature_Low_Reset_Setpoint Discharge_Air_Temperature_Low_Reset_Setpoint
Discharge_Air_Temperature_Low_Reset_Setpoint Supply_Air_Temperature_Low_Reset_Setpoint
Discharge_Air_Temperature_Proportional_Band_Parameter Discharge_Air_Temperature_Proportional_Band_Parameter
Discharge_Air_Temperature_Proportional_Band_Parameter Supply_Air_Temperature_Proportional_Band_Parameter
Discharge_Air_Temperature_Reset_Differential_Setpoint Discharge_Air_Temperature_Reset_Differential_Setpoint
Discharge_Air_Temperature_Reset_Differential_Setpoint Supply_Air_Temperature_Reset_Differential_Setpoint
Discharge_Air_Temperature_Sensor Discharge_Air_Temperature_Sensor
Discharge_Air_Temperature_Sensor Supply_Air_Temperature_Sensor
Discharge_Air_Temperature_Setpoint Discharge_Air_Temperature_Setpoint
Discharge_Air_Temperature_Setpoint Supply_Air_Temperature_Setpoint
Discharge_Air_Temperature_Setpoint_Limit Discharge_Air_Temperature_Setpoint_Limit
Discharge_Air_Temperature_Setpoint_Limit Supply_Air_Temperature_Setpoint_Limit
Discharge_Air_Temperature_Step_Parameter Discharge_Air_Temperature_Step_Parameter
Discharge_Air_Temperature_Step_Parameter Supply_Air_Temperature_Step_Parameter
Discharge_Air_Velocity_Pressure_Sensor Discharge_Air_Velocity_Pressure_Sensor
Discharge_Air_Velocity_Pressure_Sensor Supply_Air_Velocity_Pressure_Sensor
Discharge_Fan Discharge_Fan
Discharge_Fan Supply_Fan
DOAS Dedicated_Outdoor_Air_System_Unit
DOAS DOAS
Dual_Duct_Air_Handling_Unit DDAHU
Dual_Duct_Air_Handling_Unit Dual_Duct_Air_Handling_Unit
Effective_Discharge_Air_Temperature_Setpoint Effective_Discharge_Air_Temperature_Setpoint
Effective_Discharge_Air_Temperature_Setpoint Effective_Supply_Air_Temperature_Setpoint
Effective_Supply_Air_Temperature_Setpoint Effective_Discharge_Air_Temperature_Setpoint
Effective_Supply_Air_Temperature_Setpoint Effective_Supply_Air_Temperature_Setpoint
Elevator_Shaft Elevator_Shaft
Elevator_Shaft Elevator_Space
Elevator_Space Elevator_Shaft
Elevator_Space Elevator_Space
Embedded_Surface_System_Panel Embedded_Surface_System_Panel
Embedded_Surface_System_Panel ESS_Panel
ESS_Panel Embedded_Surface_System_Panel
ESS_Panel ESS_Panel
Fan_Coil_Unit Fan_Coil_Unit
Fan_Coil_Unit FCU
FCU Fan_Coil_Unit
FCU FCU
Floor Floor
Floor Storey
Heat_Exchanger Heat_Exchanger
Heat_Exchanger HX
Heating_Discharge_Air_Flow_Setpoint Heating_Discharge_Air_Flow_Setpoint
Heating_Discharge_Air_Flow_Setpoint Heating_Supply_Air_Flow_Setpoint
Heating_Discharge_Air_Temperature_Deadband_Setpoint Heating_Discharge_Air_Temperature_Deadband_Setpoint
Heating_Discharge_Air_Temperature_Deadband_Setpoint Heating_Supply_Air_Temperature_Deadband_Setpoint
Heating_Discharge_Air_Temperature_Integral_Time_Parameter Heating_Discharge_Air_Temperature_Integral_Time_Parameter
Heating_Discharge_Air_Temperature_Integral_Time_Parameter Heating_Supply_Air_Temperature_Integral_Time_Parameter
Heating_Discharge_Air_Temperature_Proportional_Band_Parameter Heating_Discharge_Air_Temperature_Proportional_Band_Parameter
Heating_Discharge_Air_Temperature_Proportional_Band_Parameter Heating_Supply_Air_Temperature_Proportional_Band_Parameter
Heating_Supply_Air_Flow_Setpoint Heating_Discharge_Air_Flow_Setpoint
Heating_Supply_Air_Flow_Setpoint Heating_Supply_Air_Flow_Setpoint
Heating_Supply_Air_Temperature_Deadband_Setpoint Heating_Discharge_Air_Temperature_Deadband_Setpoint
Heating_Supply_Air_Temperature_Deadband_Setpoint Heating_Supply_Air_Temperature_Deadband_Setpoint
Heating_Supply_Air_Temperature_Integral_Time_Parameter Heating_Discharge_Air_Temperature_Integral_Time_Parameter
Heating_Supply_Air_Temperature_Integral_Time_Parameter Heating_Supply_Air_Temperature_Integral_Time_Parameter
Heating_Supply_Air_Temperature_Proportional_Band_Parameter Heating_Discharge_Air_Temperature_Proportional_Band_Parameter
Heating_Supply_Air_Temperature_Proportional_Band_Parameter Heating_Supply_Air_Temperature_Proportional_Band_Parameter
Heating_Ventilation_Air_Conditioning_System Heating_Ventilation_Air_Conditioning_System
Heating_Ventilation_Air_Conditioning_System HVAC_System
High_Discharge_Air_Temperature_Alarm High_Discharge_Air_Temperature_Alarm
High_Discharge_Air_Temperature_Alarm High_Supply_Air_Temperature_Alarm
High_Supply_Air_Temperature_Alarm High_Discharge_Air_Temperature_Alarm
High_Supply_Air_Temperature_Alarm High_Supply_Air_Temperature_Alarm
HVAC_System Heating_Ventilation_Air_Conditioning_System
HVAC_System HVAC_System
HX Heat_Exchanger
HX HX
Low_Discharge_Air_Flow_Alarm Low_Discharge_Air_Flow_Alarm
Low_Discharge_Air_Flow_Alarm Low_Supply_Air_Flow_Alarm
Low_Discharge_Air_Temperature_Alarm Low_Discharge_Air_Temperature_Alarm
Low_Discharge_Air_Temperature_Alarm Low_Supply_Air_Temperature_Alarm
Low_Supply_Air_Flow_Alarm Low_Discharge_Air_Flow_Alarm
Low_Supply_Air_Flow_Alarm Low_Supply_Air_Flow_Alarm
Low_Supply_Air_Temperature_Alarm Low_Discharge_Air_Temperature_Alarm
Low_Supply_Air_Temperature_Alarm Low_Supply_Air_Temperature_Alarm
Makeup_Air_Unit Makeup_Air_Unit
Makeup_Air_Unit MAU
MAU Makeup_Air_Unit
MAU MAU
Max_Cooling_Discharge_Air_Flow_Setpoint_Limit Max_Cooling_Discharge_Air_Flow_Setpoint_Limit
Max_Cooling_Discharge_Air_Flow_Setpoint_Limit Max_Cooling_Supply_Air_Flow_Setpoint_Limit
Max_Cooling_Supply_Air_Flow_Setpoint_Limit Max_Cooling_Discharge_Air_Flow_Setpoint_Limit
Max_Cooling_Supply_Air_Flow_Setpoint_Limit Max_Cooling_Supply_Air_Flow_Setpoint_Limit
Max_Discharge_Air_Static_Pressure_Setpoint_Limit Max_Discharge_Air_Static_Pressure_Setpoint_Limit
Max_Discharge_Air_Static_Pressure_Setpoint_Limit Max_Supply_Air_Static_Pressure_Setpoint_Limit
Max_Discharge_Air_Temperature_Setpoint_Limit Max_Discharge_Air_Temperature_Setpoint_Limit
Max_Discharge_Air_Temperature_Setpoint_Limit Max_Supply_Air_Temperature_Setpoint_Limit
Max_Heating_Discharge_Air_Flow_Setpoint_Limit Max_Heating_Discharge_Air_Flow_Setpoint_Limit
Max_Heating_Discharge_Air_Flow_Setpoint_Limit Max_Heating_Supply_Air_Flow_Setpoint_Limit
Max_Heating_Supply_Air_Flow_Setpoint_Limit Max_Heating_Discharge_Air_Flow_Setpoint_Limit
Max_Heating_Supply_Air_Flow_Setpoint_Limit Max_Heating_Supply_Air_Flow_Setpoint_Limit
Max_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit Max_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit
Max_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit Max_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit
Max_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit Max_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit
Max_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit Max_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit
Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit
Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit Max_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit
Max_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit
Max_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit Max_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit
Max_Supply_Air_Static_Pressure_Setpoint_Limit Max_Discharge_Air_Static_Pressure_Setpoint_Limit
Max_Supply_Air_Static_Pressure_Setpoint_Limit Max_Supply_Air_Static_Pressure_Setpoint_Limit
Max_Supply_Air_Temperature_Setpoint_Limit Max_Discharge_Air_Temperature_Setpoint_Limit
Max_Supply_Air_Temperature_Setpoint_Limit Max_Supply_Air_Temperature_Setpoint_Limit
Max_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit Max_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit
Max_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit Max_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit
Max_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit Max_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit
Max_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit Max_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit
Max_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit Max_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit
Max_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit Max_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit
Max_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit Max_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit
Max_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit Max_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit
Min_Cooling_Discharge_Air_Flow_Setpoint_Limit Min_Cooling_Discharge_Air_Flow_Setpoint_Limit
Min_Cooling_Discharge_Air_Flow_Setpoint_Limit Min_Cooling_Supply_Air_Flow_Setpoint_Limit
Min_Cooling_Supply_Air_Flow_Setpoint_Limit Min_Cooling_Discharge_Air_Flow_Setpoint_Limit
Min_Cooling_Supply_Air_Flow_Setpoint_Limit Min_Cooling_Supply_Air_Flow_Setpoint_Limit
Min_Discharge_Air_Static_Pressure_Setpoint_Limit Min_Discharge_Air_Static_Pressure_Setpoint_Limit
Min_Discharge_Air_Static_Pressure_Setpoint_Limit Min_Supply_Air_Static_Pressure_Setpoint_Limit
Min_Discharge_Air_Temperature_Setpoint_Limit Min_Discharge_Air_Temperature_Setpoint_Limit
Min_Discharge_Air_Temperature_Setpoint_Limit Min_Supply_Air_Temperature_Setpoint_Limit
Min_Heating_Discharge_Air_Flow_Setpoint_Limit Min_Heating_Discharge_Air_Flow_Setpoint_Limit
Min_Heating_Discharge_Air_Flow_Setpoint_Limit Min_Heating_Supply_Air_Flow_Setpoint_Limit
Min_Heating_Supply_Air_Flow_Setpoint_Limit Min_Heating_Discharge_Air_Flow_Setpoint_Limit
Min_Heating_Supply_Air_Flow_Setpoint_Limit Min_Heating_Supply_Air_Flow_Setpoint_Limit
Min_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit Min_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit
Min_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit Min_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit
Min_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit Min_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit
Min_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit Min_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit
Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit
Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit Min_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit
Min_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit
Min_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit Min_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit
Min_Supply_Air_Static_Pressure_Setpoint_Limit Min_Discharge_Air_Static_Pressure_Setpoint_Limit
Min_Supply_Air_Static_Pressure_Setpoint_Limit Min_Supply_Air_Static_Pressure_Setpoint_Limit
Min_Supply_Air_Temperature_Setpoint_Limit Min_Discharge_Air_Temperature_Setpoint_Limit
Min_Supply_Air_Temperature_Setpoint_Limit Min_Supply_Air_Temperature_Setpoint_Limit
Min_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit Min_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit
Min_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit Min_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit
Min_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit Min_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit
Min_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit Min_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit
Min_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit Min_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit
Min_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit Min_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit
Min_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit Min_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit
Min_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit Min_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit
Network_Video_Recorder Network_Video_Recorder
Network_Video_Recorder NVR
NVR Network_Video_Recorder
NVR NVR
Occupied_Cooling_Discharge_Air_Flow_Setpoint Occupied_Cooling_Discharge_Air_Flow_Setpoint
Occupied_Cooling_Discharge_Air_Flow_Setpoint Occupied_Cooling_Supply_Air_Flow_Setpoint
Occupied_Cooling_Supply_Air_Flow_Setpoint Occupied_Cooling_Discharge_Air_Flow_Setpoint
Occupied_Cooling_Supply_Air_Flow_Setpoint Occupied_Cooling_Supply_Air_Flow_Setpoint
Occupied_Discharge_Air_Flow_Setpoint Occupied_Discharge_Air_Flow_Setpoint
Occupied_Discharge_Air_Flow_Setpoint Occupied_Supply_Air_Flow_Setpoint
Occupied_Discharge_Air_Temperature_Setpoint Occupied_Discharge_Air_Temperature_Setpoint
Occupied_Discharge_Air_Temperature_Setpoint Occupied_Supply_Air_Temperature_Setpoint
Occupied_Heating_Discharge_Air_Flow_Setpoint Occupied_Heating_Discharge_Air_Flow_Setpoint
Occupied_Heating_Discharge_Air_Flow_Setpoint Occupied_Heating_Supply_Air_Flow_Setpoint
Occupied_Heating_Supply_Air_Flow_Setpoint Occupied_Heating_Discharge_Air_Flow_Setpoint
Occupied_Heating_Supply_Air_Flow_Setpoint Occupied_Heating_Supply_Air_Flow_Setpoint
Occupied_Supply_Air_Flow_Setpoint Occupied_Discharge_Air_Flow_Setpoint
Occupied_Supply_Air_Flow_Setpoint Occupied_Supply_Air_Flow_Setpoint
Occupied_Supply_Air_Temperature_Setpoint Occupied_Discharge_Air_Temperature_Setpoint
Occupied_Supply_Air_Temperature_Setpoint Occupied_Supply_Air_Temperature_Setpoint
On_Timer_Sensor On_Timer_Sensor
On_Timer_Sensor Run_Time_Sensor
Photovoltaic_Array Photovoltaic_Array
Photovoltaic_Array PV_Array
Photovoltaic_Current_Output_Sensor Photovoltaic_Current_Output_Sensor
Photovoltaic_Current_Output_Sensor PV_Current_Output_Sensor
Preheat_Discharge_Air_Temperature_Sensor Preheat_Discharge_Air_Temperature_Sensor
Preheat_Discharge_Air_Temperature_Sensor Preheat_Supply_Air_Temperature_Sensor
Preheat_Supply_Air_Temperature_Sensor Preheat_Discharge_Air_Temperature_Sensor
Preheat_Supply_Air_Temperature_Sensor Preheat_Supply_Air_Temperature_Sensor
PV_Array Photovoltaic_Array
PV_Array PV_Array
PV_Current_Output_Sensor Photovoltaic_Current_Output_Sensor
PV_Current_Output_Sensor PV_Current_Output_Sensor
Radiant_Ceiling_Panel Radiant_Ceiling_Panel
Radiant_Ceiling_Panel RC_Panel
RC_Panel Radiant_Ceiling_Panel
RC_Panel RC_Panel
Rest_Room Rest_Room
Rest_Room Restroom
Restroom Rest_Room
Restroom Restroom
Rooftop_Unit Rooftop_Unit
Rooftop_Unit RTU
RTU Rooftop_Unit
RTU RTU
Run_Time_Sensor On_Timer_Sensor
Run_Time_Sensor Run_Time_Sensor
RVAV RVAV
RVAV Variable_Air_Volume_Box_With_Reheat
Storey Floor
Storey Storey
Supply_Air Discharge_Air
Supply_Air Supply_Air
Supply_Air_Dewpoint_Sensor Discharge_Air_Dewpoint_Sensor
Supply_Air_Dewpoint_Sensor Supply_Air_Dewpoint_Sensor
Supply_Air_Differential_Pressure_Sensor Discharge_Air_Differential_Pressure_Sensor
Supply_Air_Differential_Pressure_Sensor Supply_Air_Differential_Pressure_Sensor
Supply_Air_Differential_Pressure_Setpoint Discharge_Air_Differential_Pressure_Setpoint
Supply_Air_Differential_Pressure_Setpoint Supply_Air_Differential_Pressure_Setpoint
Supply_Air_Duct_Pressure_Status Discharge_Air_Duct_Pressure_Status
Supply_Air_Duct_Pressure_Status Supply_Air_Duct_Pressure_Status
Supply_Air_Flow_Demand_Setpoint Discharge_Air_Flow_Demand_Setpoint
Supply_Air_Flow_Demand_Setpoint Supply_Air_Flow_Demand_Setpoint
Supply_Air_Flow_High_Reset_Setpoint Discharge_Air_Flow_High_Reset_Setpoint
Supply_Air_Flow_High_Reset_Setpoint Supply_Air_Flow_High_Reset_Setpoint
Supply_Air_Flow_Low_Reset_Setpoint Discharge_Air_Flow_Low_Reset_Setpoint
Supply_Air_Flow_Low_Reset_Setpoint Supply_Air_Flow_Low_Reset_Setpoint
Supply_Air_Flow_Reset_Setpoint Discharge_Air_Flow_Reset_Setpoint
Supply_Air_Flow_Reset_Setpoint Supply_Air_Flow_Reset_Setpoint
Supply_Air_Flow_Sensor Discharge_Air_Flow_Sensor
Supply_Air_Flow_Sensor Supply_Air_Flow_Sensor
Supply_Air_Flow_Setpoint Discharge_Air_Flow_Setpoint
Supply_Air_Flow_Setpoint Supply_Air_Flow_Setpoint
Supply_Air_Humidity_Sensor Discharge_Air_Humidity_Sensor
Supply_Air_Humidity_Sensor Supply_Air_Humidity_Sensor
Supply_Air_Humidity_Setpoint Discharge_Air_Humidity_Setpoint
Supply_Air_Humidity_Setpoint Supply_Air_Humidity_Setpoint
Supply_Air_Integral_Gain_Parameter Discharge_Air_Integral_Gain_Parameter
Supply_Air_Integral_Gain_Parameter Supply_Air_Integral_Gain_Parameter
Supply_Air_Plenum Discharge_Air_Plenum
Supply_Air_Plenum Supply_Air_Plenum
Supply_Air_Proportional_Gain_Parameter Discharge_Air_Proportional_Gain_Parameter
Supply_Air_Proportional_Gain_Parameter Supply_Air_Proportional_Gain_Parameter
Supply_Air_Smoke_Detection_Alarm Discharge_Air_Smoke_Detection_Alarm
Supply_Air_Smoke_Detection_Alarm Supply_Air_Smoke_Detection_Alarm
Supply_Air_Static_Pressure_Deadband_Setpoint Discharge_Air_Static_Pressure_Deadband_Setpoint
Supply_Air_Static_Pressure_Deadband_Setpoint Supply_Air_Static_Pressure_Deadband_Setpoint
Supply_Air_Static_Pressure_Integral_Time_Parameter Discharge_Air_Static_Pressure_Integral_Time_Parameter
Supply_Air_Static_Pressure_Integral_Time_Parameter Supply_Air_Static_Pressure_Integral_Time_Parameter
Supply_Air_Static_Pressure_Proportional_Band_Parameter Discharge_Air_Static_Pressure_Proportional_Band_Parameter
Supply_Air_Static_Pressure_Proportional_Band_Parameter Supply_Air_Static_Pressure_Proportional_Band_Parameter
Supply_Air_Static_Pressure_Sensor Discharge_Air_Static_Pressure_Sensor
Supply_Air_Static_Pressure_Sensor Supply_Air_Static_Pressure_Sensor
Supply_Air_Static_Pressure_Setpoint Discharge_Air_Static_Pressure_Setpoint
Supply_Air_Static_Pressure_Setpoint Supply_Air_Static_Pressure_Setpoint
Supply_Air_Static_Pressure_Step_Parameter Discharge_Air_Static_Pressure_Step_Parameter
Supply_Air_Static_Pressure_Step_Parameter Supply_Air_Static_Pressure_Step_Parameter
Supply_Air_Temperature_Alarm Discharge_Air_Temperature_Alarm
Supply_Air_Temperature_Alarm Supply_Air_Temperature_Alarm
Supply_Air_Temperature_Cooling_Setpoint Discharge_Air_Temperature_Cooling_Setpoint
Supply_Air_Temperature_Cooling_Setpoint Supply_Air_Temperature_Cooling_Setpoint
Supply_Air_Temperature_Deadband_Setpoint Discharge_Air_Temperature_Deadband_Setpoint
Supply_Air_Temperature_Deadband_Setpoint Supply_Air_Temperature_Deadband_Setpoint
Supply_Air_Temperature_Heating_Setpoint Discharge_Air_Temperature_Heating_Setpoint
Supply_Air_Temperature_Heating_Setpoint Supply_Air_Temperature_Heating_Setpoint
Supply_Air_Temperature_High_Reset_Setpoint Discharge_Air_Temperature_High_Reset_Setpoint
Supply_Air_Temperature_High_Reset_Setpoint Supply_Air_Temperature_High_Reset_Setpoint
Supply_Air_Temperature_Low_Reset_Setpoint Discharge_Air_Temperature_Low_Reset_Setpoint
Supply_Air_Temperature_Low_Reset_Setpoint Supply_Air_Temperature_Low_Reset_Setpoint
Supply_Air_Temperature_Proportional_Band_Parameter Discharge_Air_Temperature_Proportional_Band_Parameter
Supply_Air_Temperature_Proportional_Band_Parameter Supply_Air_Temperature_Proportional_Band_Parameter
Supply_Air_Temperature_Reset_Differential_Setpoint Discharge_Air_Temperature_Reset_Differential_Setpoint
Supply_Air_Temperature_Reset_Differential_Setpoint Supply_Air_Temperature_Reset_Differential_Setpoint
Supply_Air_Temperature_Sensor Discharge_Air_Temperature_Sensor
Supply_Air_Temperature_Sensor Supply_Air_Temperature_Sensor
Supply_Air_Temperature_Setpoint Discharge_Air_Temperature_Setpoint
Supply_Air_Temperature_Setpoint Supply_Air_Temperature_Setpoint
Supply_Air_Temperature_Setpoint_Limit Discharge_Air_Temperature_Setpoint_Limit
Supply_Air_Temperature_Setpoint_Limit Supply_Air_Temperature_Setpoint_Limit
Supply_Air_Temperature_Step_Parameter Discharge_Air_Temperature_Step_Parameter
Supply_Air_Temperature_Step_Parameter Supply_Air_Temperature_Step_Parameter
Supply_Air_Velocity_Pressure_Sensor Discharge_Air_Velocity_Pressure_Sensor
Supply_Air_Velocity_Pressure_Sensor Supply_Air_Velocity_Pressure_Sensor
Supply_Fan Discharge_Fan
Supply_Fan Supply_Fan
TABS_Panel TABS_Panel
TABS_Panel Thermally_Activated_Building_System_Panel
Thermally_Activated_Building_System_Panel TABS_Panel
Thermally_Activated_Building_System_Panel Thermally_Activated_Building_System_Panel
Unoccupied_Cooling_Discharge_Air_Flow_Setpoint Unoccupied_Cooling_Discharge_Air_Flow_Setpoint
Unoccupied_Cooling_Discharge_Air_Flow_Setpoint Unoccupied_Cooling_Supply_Air_Flow_Setpoint
Unoccupied_Cooling_Supply_Air_Flow_Setpoint Unoccupied_Cooling_Discharge_Air_Flow_Setpoint
Unoccupied_Cooling_Supply_Air_Flow_Setpoint Unoccupied_Cooling_Supply_Air_Flow_Setpoint
Unoccupied_Discharge_Air_Flow_Setpoint Unoccupied_Discharge_Air_Flow_Setpoint
Unoccupied_Discharge_Air_Flow_Setpoint Unoccupied_Supply_Air_Flow_Setpoint
Unoccupied_Discharge_Air_Temperature_Setpoint Unoccupied_Discharge_Air_Temperature_Setpoint
Unoccupied_Discharge_Air_Temperature_Setpoint Unoccupied_Supply_Air_Temperature_Setpoint
Unoccupied_Heating_Discharge_Air_Flow_Setpoint Unoccupied_Heating_Discharge_Air_Flow_Setpoint
Unoccupied_Heating_Discharge_Air_Flow_Setpoint Unoccupied_Heating_Supply_Air_Flow_Setpoint
Unoccupied_Heating_Supply_Air_Flow_Setpoint Unoccupied_Heating_Discharge_Air_Flow_Setpoint
Unoccupied_Heating_Supply_Air_Flow_Setpoint Unoccupied_Heating_Supply_Air_Flow_Setpoint
Unoccupied_Supply_Air_Flow_Setpoint Unoccupied_Discharge_Air_Flow_Setpoint
Unoccupied_Supply_Air_Flow_Setpoint Unoccupied_Supply_Air_Flow_Setpoint
Unoccupied_Supply_Air_Temperature_Setpoint Unoccupied_Discharge_Air_Temperature_Setpoint
Unoccupied_Supply_Air_Temperature_Setpoint Unoccupied_Supply_Air_Temperature_Setpoint
Variable_Air_Volume_Box Variable_Air_Volume_Box
Variable_Air_Volume_Box VAV
Variable_Air_Volume_Box_With_Reheat RVAV
Variable_Air_Volume_Box_With_Reheat Variable_Air_Volume_Box_With_Reheat
Variable_Frequency_Drive Variable_Frequency_Drive
Variable_Frequency_Drive VFD
VAV Variable_Air_Volume_Box
VAV VAV
VFD Variable_Frequency_Drive
VFD VFD

Some of these classes designate a "canonical" class to use in their description, such as the skos:definition of brick:VAV saying "See Variable_Air_Volume_Box". However, this information is not consistently available and is not readable by machines.

Details (click to expand)
Class Canonical Class
DDAHU Dual_Duct_Air_Handling_Unit
DOAS Dedicated_Outdoor_Air_System_Unit
ESS_Panel Embedded_Surface_System_Panel
FCU Fan_Coil_Unit
HVAC_System Heating_Ventilation_Air_Conditioning_System
HX Heat_Exchanger
MAU Makeup_Air_Unit
PV_Current_Output_Sensor Photovoltaic_Current_Output_Sensor
RC_Panel Radiant_Ceiling_Panel
RTU Rooftop_Unit
RVAV Variable_Air_Volume_Box_With_Reheat
TABS_Panel Thermally_Activated_Building_System_Panel
VAV Variable_Air_Volume_Box

It would be great if each of the classes with an equivalent class in Brick could designate its canonical equivalent in a machine readable way.

If it's an option, I'd also propose marking the non-canonical classes as deprecated and providing a bsh:DeprecationRule to automatically switch to the canonical one.

Proposal automatically derived from the skos:definition of each class (either the class in "See <class>", or the longer the better):

Click to expand
Class Canonical Class
AED Automated_External_Defibrillator
AHU Air_Handler_Unit
Air_Handler_Unit Air_Handler_Unit
Air_Handling_Unit Air_Handler_Unit
Automated_External_Defibrillator Automated_External_Defibrillator
Average_Discharge_Air_Flow_Sensor Average_Discharge_Air_Flow_Sensor
Average_Supply_Air_Flow_Sensor Average_Discharge_Air_Flow_Sensor
CAV Constant_Air_Volume_Box
Computer_Room_Air_Conditioning Computer_Room_Air_Conditioning
Computer_Room_Air_Handler Computer_Room_Air_Handler
Constant_Air_Volume_Box Constant_Air_Volume_Box
Cooling_Discharge_Air_Flow_Setpoint Cooling_Supply_Air_Flow_Setpoint
Cooling_Discharge_Air_Temperature_Deadband_Setpoint Cooling_Supply_Air_Temperature_Deadband_Setpoint
Cooling_Discharge_Air_Temperature_Integral_Time_Parameter Cooling_Discharge_Air_Temperature_Integral_Time_Parameter
Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter
Cooling_Supply_Air_Flow_Setpoint Cooling_Supply_Air_Flow_Setpoint
Cooling_Supply_Air_Temperature_Deadband_Setpoint Cooling_Supply_Air_Temperature_Deadband_Setpoint
Cooling_Supply_Air_Temperature_Integral_Time_Parameter Cooling_Discharge_Air_Temperature_Integral_Time_Parameter
Cooling_Supply_Air_Temperature_Proportional_Band_Parameter Cooling_Discharge_Air_Temperature_Proportional_Band_Parameter
CRAC Computer_Room_Air_Conditioning
CRAH Computer_Room_Air_Handler
DDAHU Dual_Duct_Air_Handling_Unit
Dedicated_Outdoor_Air_System_Unit Dedicated_Outdoor_Air_System_Unit
Discharge_Air Supply_Air
Discharge_Air_Dewpoint_Sensor Discharge_Air_Dewpoint_Sensor
Discharge_Air_Differential_Pressure_Sensor Supply_Air_Differential_Pressure_Sensor
Discharge_Air_Differential_Pressure_Setpoint Supply_Air_Differential_Pressure_Setpoint
Discharge_Air_Duct_Pressure_Status Discharge_Air_Duct_Pressure_Status
Discharge_Air_Flow_Demand_Setpoint Discharge_Air_Flow_Demand_Setpoint
Discharge_Air_Flow_High_Reset_Setpoint Discharge_Air_Flow_High_Reset_Setpoint
Discharge_Air_Flow_Low_Reset_Setpoint Discharge_Air_Flow_Low_Reset_Setpoint
Discharge_Air_Flow_Reset_Setpoint Discharge_Air_Flow_Reset_Setpoint
Discharge_Air_Flow_Sensor Discharge_Air_Flow_Sensor
Discharge_Air_Flow_Setpoint Supply_Air_Flow_Setpoint
Discharge_Air_Humidity_Sensor Discharge_Air_Humidity_Sensor
Discharge_Air_Humidity_Setpoint Discharge_Air_Humidity_Setpoint
Discharge_Air_Integral_Gain_Parameter Discharge_Air_Integral_Gain_Parameter
Discharge_Air_Plenum Supply_Air_Plenum
Discharge_Air_Proportional_Gain_Parameter Discharge_Air_Proportional_Gain_Parameter
Discharge_Air_Smoke_Detection_Alarm Discharge_Air_Smoke_Detection_Alarm
Discharge_Air_Static_Pressure_Deadband_Setpoint Discharge_Air_Static_Pressure_Deadband_Setpoint
Discharge_Air_Static_Pressure_Integral_Time_Parameter Discharge_Air_Static_Pressure_Integral_Time_Parameter
Discharge_Air_Static_Pressure_Proportional_Band_Parameter Discharge_Air_Static_Pressure_Proportional_Band_Parameter
Discharge_Air_Static_Pressure_Sensor Discharge_Air_Static_Pressure_Sensor
Discharge_Air_Static_Pressure_Setpoint Discharge_Air_Static_Pressure_Setpoint
Discharge_Air_Static_Pressure_Step_Parameter Discharge_Air_Static_Pressure_Step_Parameter
Discharge_Air_Temperature_Alarm Discharge_Air_Temperature_Alarm
Discharge_Air_Temperature_Cooling_Setpoint Discharge_Air_Temperature_Cooling_Setpoint
Discharge_Air_Temperature_Deadband_Setpoint Discharge_Air_Temperature_Deadband_Setpoint
Discharge_Air_Temperature_Heating_Setpoint Discharge_Air_Temperature_Heating_Setpoint
Discharge_Air_Temperature_High_Reset_Setpoint Discharge_Air_Temperature_High_Reset_Setpoint
Discharge_Air_Temperature_Low_Reset_Setpoint Discharge_Air_Temperature_Low_Reset_Setpoint
Discharge_Air_Temperature_Proportional_Band_Parameter Discharge_Air_Temperature_Proportional_Band_Parameter
Discharge_Air_Temperature_Reset_Differential_Setpoint Discharge_Air_Temperature_Reset_Differential_Setpoint
Discharge_Air_Temperature_Sensor Discharge_Air_Temperature_Sensor
Discharge_Air_Temperature_Setpoint Supply_Air_Temperature_Setpoint
Discharge_Air_Temperature_Setpoint_Limit Discharge_Air_Temperature_Setpoint_Limit
Discharge_Air_Temperature_Step_Parameter Discharge_Air_Temperature_Step_Parameter
Discharge_Air_Velocity_Pressure_Sensor Discharge_Air_Velocity_Pressure_Sensor
Discharge_Fan Supply_Fan
DOAS Dedicated_Outdoor_Air_System_Unit
Dual_Duct_Air_Handling_Unit Dual_Duct_Air_Handling_Unit
Effective_Discharge_Air_Temperature_Setpoint Effective_Discharge_Air_Temperature_Setpoint
Effective_Supply_Air_Temperature_Setpoint Effective_Discharge_Air_Temperature_Setpoint
Embedded_Surface_System_Panel Embedded_Surface_System_Panel
ESS_Panel Embedded_Surface_System_Panel
Fan_Coil_Unit Fan_Coil_Unit
FCU Fan_Coil_Unit
Heat_Exchanger Heat_Exchanger
Heating_Discharge_Air_Flow_Setpoint Heating_Supply_Air_Flow_Setpoint
Heating_Discharge_Air_Temperature_Deadband_Setpoint Heating_Supply_Air_Temperature_Deadband_Setpoint
Heating_Discharge_Air_Temperature_Integral_Time_Parameter Heating_Discharge_Air_Temperature_Integral_Time_Parameter
Heating_Discharge_Air_Temperature_Proportional_Band_Parameter Heating_Discharge_Air_Temperature_Proportional_Band_Parameter
Heating_Supply_Air_Flow_Setpoint Heating_Supply_Air_Flow_Setpoint
Heating_Supply_Air_Temperature_Deadband_Setpoint Heating_Supply_Air_Temperature_Deadband_Setpoint
Heating_Supply_Air_Temperature_Integral_Time_Parameter Heating_Discharge_Air_Temperature_Integral_Time_Parameter
Heating_Supply_Air_Temperature_Proportional_Band_Parameter Heating_Discharge_Air_Temperature_Proportional_Band_Parameter
Heating_Ventilation_Air_Conditioning_System Heating_Ventilation_Air_Conditioning_System
High_Discharge_Air_Temperature_Alarm High_Discharge_Air_Temperature_Alarm
High_Supply_Air_Temperature_Alarm High_Discharge_Air_Temperature_Alarm
HVAC_System Heating_Ventilation_Air_Conditioning_System
HX Heat_Exchanger
Low_Discharge_Air_Flow_Alarm Low_Discharge_Air_Flow_Alarm
Low_Discharge_Air_Temperature_Alarm Low_Discharge_Air_Temperature_Alarm
Low_Supply_Air_Flow_Alarm Low_Discharge_Air_Flow_Alarm
Low_Supply_Air_Temperature_Alarm Low_Discharge_Air_Temperature_Alarm
Makeup_Air_Unit Makeup_Air_Unit
MAU Makeup_Air_Unit
Max_Cooling_Discharge_Air_Flow_Setpoint_Limit Max_Cooling_Discharge_Air_Flow_Setpoint_Limit
Max_Cooling_Supply_Air_Flow_Setpoint_Limit Max_Cooling_Discharge_Air_Flow_Setpoint_Limit
Max_Discharge_Air_Static_Pressure_Setpoint_Limit Max_Discharge_Air_Static_Pressure_Setpoint_Limit
Max_Discharge_Air_Temperature_Setpoint_Limit Max_Discharge_Air_Temperature_Setpoint_Limit
Max_Heating_Discharge_Air_Flow_Setpoint_Limit Max_Heating_Discharge_Air_Flow_Setpoint_Limit
Max_Heating_Supply_Air_Flow_Setpoint_Limit Max_Heating_Discharge_Air_Flow_Setpoint_Limit
Max_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit Max_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit
Max_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit Max_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit
Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit
Max_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit Max_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit
Max_Supply_Air_Static_Pressure_Setpoint_Limit Max_Discharge_Air_Static_Pressure_Setpoint_Limit
Max_Supply_Air_Temperature_Setpoint_Limit Max_Discharge_Air_Temperature_Setpoint_Limit
Max_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit Max_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit
Max_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit Max_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit
Max_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit Max_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit
Max_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit Max_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit
Min_Cooling_Discharge_Air_Flow_Setpoint_Limit Min_Cooling_Discharge_Air_Flow_Setpoint_Limit
Min_Cooling_Supply_Air_Flow_Setpoint_Limit Min_Cooling_Discharge_Air_Flow_Setpoint_Limit
Min_Discharge_Air_Static_Pressure_Setpoint_Limit Min_Discharge_Air_Static_Pressure_Setpoint_Limit
Min_Discharge_Air_Temperature_Setpoint_Limit Min_Discharge_Air_Temperature_Setpoint_Limit
Min_Heating_Discharge_Air_Flow_Setpoint_Limit Min_Heating_Discharge_Air_Flow_Setpoint_Limit
Min_Heating_Supply_Air_Flow_Setpoint_Limit Min_Heating_Discharge_Air_Flow_Setpoint_Limit
Min_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit Min_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit
Min_Occupied_Cooling_Supply_Air_Flow_Setpoint_Limit Min_Occupied_Cooling_Discharge_Air_Flow_Setpoint_Limit
Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit
Min_Occupied_Heating_Supply_Air_Flow_Setpoint_Limit Min_Occupied_Heating_Discharge_Air_Flow_Setpoint_Limit
Min_Supply_Air_Static_Pressure_Setpoint_Limit Min_Discharge_Air_Static_Pressure_Setpoint_Limit
Min_Supply_Air_Temperature_Setpoint_Limit Min_Discharge_Air_Temperature_Setpoint_Limit
Min_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit Min_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit
Min_Unoccupied_Cooling_Supply_Air_Flow_Setpoint_Limit Min_Unoccupied_Cooling_Discharge_Air_Flow_Setpoint_Limit
Min_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit Min_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit
Min_Unoccupied_Heating_Supply_Air_Flow_Setpoint_Limit Min_Unoccupied_Heating_Discharge_Air_Flow_Setpoint_Limit
Network_Video_Recorder Network_Video_Recorder
NVR Network_Video_Recorder
Occupied_Cooling_Discharge_Air_Flow_Setpoint Occupied_Cooling_Supply_Air_Flow_Setpoint
Occupied_Cooling_Supply_Air_Flow_Setpoint Occupied_Cooling_Supply_Air_Flow_Setpoint
Occupied_Discharge_Air_Flow_Setpoint Occupied_Supply_Air_Flow_Setpoint
Occupied_Discharge_Air_Temperature_Setpoint Occupied_Discharge_Air_Temperature_Setpoint
Occupied_Heating_Discharge_Air_Flow_Setpoint Occupied_Heating_Supply_Air_Flow_Setpoint
Occupied_Heating_Supply_Air_Flow_Setpoint Occupied_Heating_Supply_Air_Flow_Setpoint
Occupied_Supply_Air_Flow_Setpoint Occupied_Supply_Air_Flow_Setpoint
Occupied_Supply_Air_Temperature_Setpoint Occupied_Discharge_Air_Temperature_Setpoint
On_Timer_Sensor On_Timer_Sensor
Photovoltaic_Array Photovoltaic_Array
Photovoltaic_Current_Output_Sensor Photovoltaic_Current_Output_Sensor
Preheat_Discharge_Air_Temperature_Sensor Preheat_Discharge_Air_Temperature_Sensor
Preheat_Supply_Air_Temperature_Sensor Preheat_Discharge_Air_Temperature_Sensor
PV_Array Photovoltaic_Array
PV_Current_Output_Sensor Photovoltaic_Current_Output_Sensor
Radiant_Ceiling_Panel Radiant_Ceiling_Panel
RC_Panel Radiant_Ceiling_Panel
Rooftop_Unit Rooftop_Unit
RTU Rooftop_Unit
Run_Time_Sensor On_Timer_Sensor
RVAV Variable_Air_Volume_Box_With_Reheat
Supply_Air Supply_Air
Supply_Air_Dewpoint_Sensor Discharge_Air_Dewpoint_Sensor
Supply_Air_Differential_Pressure_Sensor Supply_Air_Differential_Pressure_Sensor
Supply_Air_Differential_Pressure_Setpoint Supply_Air_Differential_Pressure_Setpoint
Supply_Air_Duct_Pressure_Status Discharge_Air_Duct_Pressure_Status
Supply_Air_Flow_Demand_Setpoint Discharge_Air_Flow_Demand_Setpoint
Supply_Air_Flow_High_Reset_Setpoint Discharge_Air_Flow_High_Reset_Setpoint
Supply_Air_Flow_Low_Reset_Setpoint Discharge_Air_Flow_Low_Reset_Setpoint
Supply_Air_Flow_Reset_Setpoint Discharge_Air_Flow_Reset_Setpoint
Supply_Air_Flow_Sensor Discharge_Air_Flow_Sensor
Supply_Air_Flow_Setpoint Supply_Air_Flow_Setpoint
Supply_Air_Humidity_Sensor Discharge_Air_Humidity_Sensor
Supply_Air_Humidity_Setpoint Discharge_Air_Humidity_Setpoint
Supply_Air_Integral_Gain_Parameter Discharge_Air_Integral_Gain_Parameter
Supply_Air_Plenum Supply_Air_Plenum
Supply_Air_Proportional_Gain_Parameter Discharge_Air_Proportional_Gain_Parameter
Supply_Air_Smoke_Detection_Alarm Discharge_Air_Smoke_Detection_Alarm
Supply_Air_Static_Pressure_Deadband_Setpoint Discharge_Air_Static_Pressure_Deadband_Setpoint
Supply_Air_Static_Pressure_Integral_Time_Parameter Discharge_Air_Static_Pressure_Integral_Time_Parameter
Supply_Air_Static_Pressure_Proportional_Band_Parameter Discharge_Air_Static_Pressure_Proportional_Band_Parameter
Supply_Air_Static_Pressure_Sensor Discharge_Air_Static_Pressure_Sensor
Supply_Air_Static_Pressure_Setpoint Discharge_Air_Static_Pressure_Setpoint
Supply_Air_Static_Pressure_Step_Parameter Discharge_Air_Static_Pressure_Step_Parameter
Supply_Air_Temperature_Alarm Discharge_Air_Temperature_Alarm
Supply_Air_Temperature_Cooling_Setpoint Discharge_Air_Temperature_Cooling_Setpoint
Supply_Air_Temperature_Deadband_Setpoint Discharge_Air_Temperature_Deadband_Setpoint
Supply_Air_Temperature_Heating_Setpoint Discharge_Air_Temperature_Heating_Setpoint
Supply_Air_Temperature_High_Reset_Setpoint Discharge_Air_Temperature_High_Reset_Setpoint
Supply_Air_Temperature_Low_Reset_Setpoint Discharge_Air_Temperature_Low_Reset_Setpoint
Supply_Air_Temperature_Proportional_Band_Parameter Discharge_Air_Temperature_Proportional_Band_Parameter
Supply_Air_Temperature_Reset_Differential_Setpoint Discharge_Air_Temperature_Reset_Differential_Setpoint
Supply_Air_Temperature_Sensor Discharge_Air_Temperature_Sensor
Supply_Air_Temperature_Setpoint Supply_Air_Temperature_Setpoint
Supply_Air_Temperature_Setpoint_Limit Discharge_Air_Temperature_Setpoint_Limit
Supply_Air_Temperature_Step_Parameter Discharge_Air_Temperature_Step_Parameter
Supply_Air_Velocity_Pressure_Sensor Discharge_Air_Velocity_Pressure_Sensor
Supply_Fan Supply_Fan
TABS_Panel Thermally_Activated_Building_System_Panel
Thermally_Activated_Building_System_Panel Thermally_Activated_Building_System_Panel
Unoccupied_Cooling_Discharge_Air_Flow_Setpoint Unoccupied_Cooling_Discharge_Air_Flow_Setpoint
Unoccupied_Cooling_Supply_Air_Flow_Setpoint Unoccupied_Cooling_Discharge_Air_Flow_Setpoint
Unoccupied_Discharge_Air_Flow_Setpoint Unoccupied_Discharge_Air_Flow_Setpoint
Unoccupied_Discharge_Air_Temperature_Setpoint Unoccupied_Discharge_Air_Temperature_Setpoint
Unoccupied_Heating_Discharge_Air_Flow_Setpoint Unoccupied_Heating_Discharge_Air_Flow_Setpoint
Unoccupied_Heating_Supply_Air_Flow_Setpoint Unoccupied_Heating_Discharge_Air_Flow_Setpoint
Unoccupied_Supply_Air_Flow_Setpoint Unoccupied_Discharge_Air_Flow_Setpoint
Unoccupied_Supply_Air_Temperature_Setpoint Unoccupied_Discharge_Air_Temperature_Setpoint
Variable_Air_Volume_Box Variable_Air_Volume_Box
Variable_Air_Volume_Box_With_Reheat Variable_Air_Volume_Box_With_Reheat
Variable_Frequency_Drive Variable_Frequency_Drive
VAV Variable_Air_Volume_Box
VFD Variable_Frequency_Drive

Couple suggestions from discussion today:

  • add a boolean-typed datatype property (brick:isAlias?) to mark the alias classes
  • keep the non-canonical classes for now, but infer the canonical classes using SHACL shapes. Don't mark them as deprecated for now

@MatthewSteen do you have time to help us pick out the best canonical form from the tables above?

@gtfierro yes, I'll take a look today.

I'd love to get @steveraysteveray opinion on a best practice for designating an alias - is there something better than us making up a new brick:isAlias property?

We have run into the need for this many times in the QUDT ontology, and use qudt:exactMatch to indicate that two URIs really mean the same concept. Designed to mimic skos:exactMatch in some (but not all) ways, qudt:exactMatch allows QUDT to deliver multiple representations of the same concept in a machine-approachable way. One common example for QUDT is the "common interpretation" versus the "pedantically correct interpretation", such as:

  • quantitykind:Angle = quantitykind:PlaneAngle (because there is also quantitykind:SolidAngle)
  • quantitykind:Acceleration = quantitykind:LinearAcceleration (because there is also quantitykind:AngularAcceleration)
    Our approach has been to define the common (yet ambiguous) term as an exact match with the more pedantic (and unambiguous) term.

Also, some concepts are just known by different terms:

  • quantitykind:ElectricDisplacement = quantitykind:ElectricFluxDensity
  • unit:AMU (Atomic Mass Unit) = unit:Da (Dalton) = unit:U (Unified Atomic Mass Unit)
  • unit:J (Joule) = unit:NM (Newton Metre)

The reasons we don't just use skos:exactMatch are:

  1. We have control over the assumptions, now and in the future
  2. the SKOS mapping relations "are used to state mapping (alignment) links between SKOS concepts in different concept schemes". see https://www.w3.org/TR/skos-reference/#mapping, so this is one example of a case where qudt:exactMatch doesn't mean quite the same thing as skos:exactMatch, since we use it to relate concepts within the same ontology.
  3. The alternatives are not precisely identical in our model, since they have distinct descriptions and labels (for example), but semantically they are equivalent.

So bottom line, we don't try to identify the "canonical" term if there are popular alternatives.

Hope this helps.

I really like the distinction you drew between "common" and "pedantically correct" definitions --- I think that characterizes much of what we're dealing with in Brick (and 223P!).

Are there any rules / semantics associated with qudt:exactMatch? I see from https://qudt.org/schema/qudt/exactMatch that it is a subproperty of owl:sameAs, but I don't know if you're using those semantics for QUDT.

For Brick, to enforce canonical identifiers, we might do "one way" inference: uses of the common terms are inferred to be their preferred, canonical equivalents; but we do not infer the common terms from the canonical terms.

As we move toward considering the SHACL schema as the master schema for QUDT, the link between qudt:exactMatch and owl:sameAs disappears. In fact, we don't think of them as identical, as I mentioned above.

Your one-way approach for the canonical terms sounds reasonable.

I've made some progress on the Equipment classes. Feel free to comment on the PR or start a Discussion in the repo.

@MatthewSteen that is fantastic! I will dig into that soon. Thanks so much for taking the time to put that together