CAT021 - problem decoding Military Extended Squitter in Reserved Expansion Field
tmartincevic opened this issue · 3 comments
tmartincevic commented
Using install/config/asterix_cat021_2_4.xml. Trying to decode Mode 5 Summary in Military Extended Squitter, Reserved Expansion Field does not produce expected output. There are several issues in the RE section of the config file. Network capture as well as updated config file are attached.
-------------------------
Data Block 1
Category: 21
Len: 13
-------------------------
Data Record 1
Len: 13
CRC: 80D4EFBB
Timestamp: 52888414
HexData: 15001081010101010104D27D04018081
Item 010 : Data Source Identification
[ D2 7D ]
System Area Code: 210
System Identification Code: 125
Item RE : Reserved Expansion Field
[ 04 01 80 81 ]
Spare bits set to zero: 8
Warning: Value should be set to 0
Barometric Pressure Setting: 264 (26.4000000 mb)
Spare bits set to zero: 0
Barometric Pressure Setting: 2048 (204.8000000 mb)
tmartincevic commented
More updates to config file (ignore the one from the original post):
asterix_cat021_2_4.zip
dsalantic commented
Thanks for your fix. I merged your changes except the SelHHRD to HRD item rename, because HRD already exists in same category.
tmartincevic commented
Thank you for catching the duplicate name.