Deltares/SFINCS

Backwards compatibility discharge and weir modelling issue

Leynse opened this issue · 3 comments

Backwards compatibility discharge and weir modelling issue
  • Problem arrises when running an old model with tidal and upstream discharge forcing, the fluxes are lower than with the old prerelease SVN openacc_11_rev394_01072022 version
  • Seems to be related to runnin advection=0 with theta<1.0 (here 0.95)
  • Might be related to added smoothing for that case in commit f8b95a2 of 01-11-2022

Latest revision might have resolved this. @Leynse: could please give this another try?

Leynse commented

Yes this is fixed in the recent main, excellent!