User setting for Networks quantity

Opened this issue · 0 comments

Max number of networks is currently 400 but the user may want to execute a lower quantity to improve scan time
As reference 100 networks are executed at 0.5/0.6 ms of cycle time
10 Networks are evaluated at 0.1 ms or faster