EvanMulawski/FanControl.CorsairLink

Commander Core ELITE CAPELLIX: The expected data type was not read within the specified time.

Closed this issue · 5 comments

I haven't gotten this plugin to work, every time I launch it it gives me this error.
I am using a Corsair H100i Elite LCD with the included Capellix Commander Pro, I just double checked all the wiring everywhere and there are no issues on that. The devices are showing up in device manager. I have tried installing the driver included in the .zip file in case that did anything but it did not.
I am using v173 FanControl 4_8 and V1.4.1 CorsairLink.

The message in the log says Operation canceled: The expected data type was not read within the specified time.
Help would be appreciated

Logs:
CorsairLink.log
log.txt

Hi @Tcris1000, please try the build linked in #112 (comment). Let me know if that works and post the CorsairLink.log file after testing.

It still didn't work, I think it gave a different error though
I also removed the driver as it was saying there were 0 devices for it

CorsairLink.log

@Tcris1000 Do you have any other software running that would be communicating with the device? e.g. OpenRGB, SignalRGB, iCUE, etc.

I just tried it again right now with the other build and it worked this time. As far as I know nothing changed, it just worked this time. I think previously I might have accidentally still been using the normal, most recent build. But it is working currently with the build from #112. Thanks for the help!

Fixed in v1.4.2