ForwardCom/manual

Opcode mismatch for make_sequence

Closed this issue · 1 comments

Table 4.7 notes the used opcode as 3, whereas the description in chapter 5.3 shows opcode 4.
I'm fairly certain 3 is the right one, because 4 is already occupied by the insert instruction.

You are right. Thanks for checking