Battery extender issue - Framework 13 AMD Ryzen AI 300
Opened this issue · 3 comments
Device Information
System Model or SKU
- Framework Laptop 13 (AMD Ryzen™ AI 300 Series)
BIOS VERSION
03.04
Standalone Operation
- No
Describe the bug
The battery extender setting is not working.
Steps To Reproduce
Battery fully charged to 100%
After 10 days and not removing the power, the laptop is always staying at 99-100%.
Changed setting to 3 days, after 7 days always at 99-100%
Also tried to use the laptop at battery for a hour (setting to 30 minute) and plug in.
Same result, permanently staying at 99-100%
At 99% it is saying charging and few minutes later it changes to 100%.
Operating System:
- OS/Distribution: Lubuntu
- Version: 25.04
- Linux Kernel Version: Linux framework13 6.14.0-29-generic #29-Ubuntu SMP PREEMPT_DYNAMIC Thu Aug 7 18:32:38 UTC 2025 x86_64 x86_64 x86_64 GNU/Linux
Screenshot:
Update for this issue: Laptop was since the last post (approx 2 weeks) constantly on the power line.
Current battery state: 100%, fully charged.
@Contralto0 Could you help to provide your BIOS settings about the battery extender?
Also, there are 2 mechanisms that will reset the battery extender timer.
- During the "Battery Extender Trigger" days (Default is 5 days), entering the BIOS setup menu and then saving and exiting will reset the timer.
- Removing the AC adapter for more than 30 minutes(Default) will reset the timer. You can modify the value of "Battery Extender Reset" in BIOS
@quinchou77 Yes, see attached.
For your two points: I have during this time always plugged the laptop in (now for more then 3 weeks) and have not changed or saved any bios setting, so the counter should not reset.