Release v1.0.13 breaks CO2 sensor for *my* Pure A9
Closed this issue · 6 comments
jesperll commented
Latest release v1.0.13 broke CO2 sensor for my Pure A9
I see a fix (#72) was merged for specifically that model but it looks like our models return different data. Might be firmware version specific.
Here's how my json looks like from the debug log:
{
"applianceData": {
"applianceName": "Luftrenser",
"created": "2024-02-03T16: 11: 15.5034292Z",
"modelName": "PUREA9"
},
"properties": {
"reported": {
"FrmVer_NIU": "2.21",
"Workmode": "Auto",
"Fanspeed": 2,
"UILight": true,
"SafetyLock": false,
"Ionizer": true,
"FilterType": 99,
"DspIcoTVOC": true,
"ErrPM2_5": false,
"ErrTVOC": false,
"ErrTempHumidity": false,
"ErrFanMtr": false,
"ErrCommSensorDisplayBrd": false,
"DoorOpen": false,
"ErrRFID": false,
"SignalStrength": "FAIR",
"$version": 6,
"PM1": 0,
"PM2_5": 0,
"PM10": 0,
"Temp": 21,
"Humidity": 54,
"RSSI": -64,
"CO2": 1018,
"TVOC": 111
}
}
}
WouterNordsiek commented
Same here also A9
PsychoV3 commented
CO2 sensor appears now to be eCO2....
JohNan commented
I see, it looks like like we probably need both then. If the attribute doesn't exist it shouldn't be visible anyhow. I'll add it back as soon as I can.
JohNan commented
I just pushed a new version. Let me know if it works now.
hermanops commented
Still works for me.
debug log shows no CO2 for 'FrmVer_NIU': '3.0.1'. Looks like we only have ECO2.
WouterNordsiek commented