MK-2001/ioBroker.go-e

cant write single temps - expected 3 elements got only 2..

Ilovegym66 opened this issue · 3 comments

With update to 051.4 of the Wallbox the adapter with version 1.0.15 I got no temperatures in the objects and this error message:
2021-09-28 22:17:26.593 - debug: go-e.0 (101837) state go-e.0.ampere changed: 16 (ack = true) namespace: go-e.0 2021-09-28 22:17:26.596 - debug: go-e.0 (101837) state go-e.0.amperePV changed: 0 (ack = true) namespace: go-e.0 2021-09-28 22:17:26.599 - debug: go-e.0 (101837) state go-e.0.access_state changed: 1 (ack = true) namespace: go-e.0 2021-09-28 22:17:26.601 - debug: go-e.0 (101837) state go-e.0.allow_charging changed: 0 (ack = true) namespace: go-e.0 2021-09-28 22:17:26.603 - debug: go-e.0 (101837) state go-e.0.stop_state changed: 0 (ack = true) namespace: go-e.0 2021-09-28 22:17:26.649 - debug: go-e.0 (101837) state go-e.0.max_load changed: 50 (ack = true) namespace: go-e.0 2021-09-28 22:17:26.667 - debug: go-e.0 (101837) state go-e.0.settings.ampere_level1 changed: 6 (ack = true) namespace: go-e.0 2021-09-28 22:17:26.669 - debug: go-e.0 (101837) state go-e.0.settings.ampere_level2 changed: 10 (ack = true) namespace: go-e.0 2021-09-28 22:17:26.671 - debug: go-e.0 (101837) state go-e.0.settings.ampere_level3 changed: 12 (ack = true) namespace: go-e.0 2021-09-28 22:17:26.673 - debug: go-e.0 (101837) state go-e.0.settings.ampere_level4 changed: 14 (ack = true) namespace: go-e.0 2021-09-28 22:17:26.674 - debug: go-e.0 (101837) state go-e.0.settings.ampere_level5 changed: 16 (ack = true) namespace: go-e.0 2021-09-28 22:17:26.677 - debug: go-e.0 (101837) state go-e.0.settings.color.idle changed: #ff (ack = true) namespace: go-e.0 2021-09-28 22:17:26.678 - debug: go-e.0 (101837) state go-e.0.settings.color.charging changed: #ffff (ack = true) namespace: go-e.0 2021-09-28 22:17:26.680 - debug: go-e.0 (101837) state go-e.0.settings.color.finish changed: #ff00 (ack = true) namespace: go-e.0 2021-09-28 22:17:26.747 - info: go-e.0 (101837) State value to set for "go-e.0.temperatures.tempereatureArray" has to be stringified but received type "object" 2021-09-28 22:17:26.748 - debug: go-e.0 (101837) Cant write temp single temps. Expected 3 elements got ["18.125","22.875"] 2021-09-28 22:17:26.761 - debug: go-e.0 (101837) state go-e.0.unlock_state changed: 0 (ack = true) namespace: go-e.0 2021-09-28 22:17:56.437 - debug: go-e.0 (101837) Starte Abfrage an: http://192.168.0.124/status 2021-09-28 22:17:56.663 - debug: go-e.0 (101837) Response: 200 - OK with data as object 2021-09-28 22:17:56.663 - debug: go-e.0 (101837) {"version":"B","tme":"2809212217","rbc":"10","rbt":"20814595","car":"1","amx":"0","amp":"16","err":"0","ast":"1","alw":"0","stp":"0","cbl":"0","pha":"56","fsp":"0","tma":[18.125,22.875],"dws":"2457353","dwo":"500","adi":"1","uby":"0","eto":"148","wst":"3","fwv":"051.4","nrg":[234,235,234,0,0,0,0,0,0,0,0,0,0,0,0,0],"sse":"059285","wss":"MITS","wke":"********","wen":"1","cdi":"0","tof":"101","tds":"1","lbr":"149","aho":"0","afi":"6","azo":"1","ama":"16","al1":"6","al2":"10","al3":"12","al4":"14","al5":"16","cid":"255","cch":"65535","cfi":"65280","lse":"1","ust":"0","wak":"********","r1x":"2","dto":"0","nmo":"0","sch":"AAAAAAAAAAAAAAAA","sdp":"0","eca":"0","ecr":"0","ecd":"0","ec4":"0","ec5":"0","ec6":"0","ec7":"0","ec8":"0","ec9":"0","ec1":"0","rca":"1","rcr":"1","rcd":"","rc4":"","rc5":"","rc6":"","rc7":"","rc8":"","rc9":"","rc1":"","rna":"ChipGoE","rnm":"BlueChip","rne":"User 3","rn4":"User 4","rn5":"User 5","rn6":"User 6","rn7":"User 7","rn8":"User 8","rn9":"User 9","rn1":"User 10","loe":0,"lot":32,"lom":6,"lop":50,"log":"","lof":0,"loa":0,"lch":259}

grafik

@MK-2001 Update in progress?

Hi. HW Version 3 ist derzeit nicht unterstützt.
"051.4"

Ich selber besitze nur die Version 2 un kann daher nicht gegen HW V3 Programmieren. Ich habe bereits in der Fa. angefragt, ob ich für die Programmierarbeiten eine HW erstehen könnte, leider ohne jegliche Rückmeldung.

Ahh ok.