Angle between slot and holes of Cams Set 2 is different

greg-bakker opened this issue · 0 comments

On the Cams Set 2 the angle between the slot and the two holes is 61.7 degrees instead of 60 degrees like on Set 1 and Set 3 (see the two attached images with noted dimensions of a cam from Set 2 and Set 3, with angle circled in red). As a note, the slots are 8.3 mm and the shaft it slides over is 8mm, so there probably is enough clearance that it will not bother much. But I just wanted to bring it to your attention.
CAM2L_dimensions
CAM3L_dimensions