ism330dhcx temperature in wrong format
Paplewski opened this issue · 1 comments
Paplewski commented
According to the IIO ABI documentation the temperature output units are standardized:
Units after application of scale and offset are milli degrees Celsius.
Applying the following patch solves the problem.
Subject: [PATCH 1/1] Fix temperature scaling issue
According to the iio ABI documentation the units of the temperature
is mili degrees Celsius.
---
drivers/iio/imu/st_ism330dhcx/st_ism330dhcx_core.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/iio/imu/st_ism330dhcx/st_ism330dhcx_core.c b/drivers/iio/imu/st_ism330dhcx/st_ism330dhcx_core.c
index 07e8e2d77f5f..9939c65a1e51 100644
--- a/drivers/iio/imu/st_ism330dhcx/st_ism330dhcx_core.c
+++ b/drivers/iio/imu/st_ism330dhcx/st_ism330dhcx_core.c
@@ -781,7 +781,7 @@ static int st_ism330dhcx_read_raw(struct iio_dev *iio_dev,
case IIO_CHAN_INFO_SCALE:
switch (ch->type) {
case IIO_TEMP:
- *val = 1;
+ *val = 1000;
*val2 = ST_ISM330DHCX_TEMP_GAIN;
ret = IIO_VAL_FRACTIONAL;
break;
Edit: Currently the units are degrees C
mariotesi commented
pls consider update driver are moved on new github repository: