Check residual load calculation
Closed this issue · 2 comments
dlr-jk commented
Problem description
@IngridJSJ found residual load shapes to be somewhat odd for future scenarios.
Action
Check residual load calculation for correctness and adjust in case it proofs erroneous.
dlr-jk commented
It has been checked. From a computational point of, it is all calculated correctly. The point is that actual RES infeed (after curtailment) is compared with planned demand. It might be an option, to also incorporate RES production potential. @IngridJSJ: Would it be interesting to additionally write out the residual load considering RES potentials?
dlr-jk commented
This will be closed in favor of another dedicated issue to write out planned demand as well as RES generation potentials.