Macro Oscillator 2/Pair of Classic Waveforms - No Aux output until Harmonics control moved
Opened this issue · 1 comments
To reproduce:
Load Macro 2 Oscillator with VU meter (like AS MonoVUmeter). connect Aux output of Macro 2 to input of the Vumeter. You will see no signal. Then move the Harmonics control and you will immediately see output on the Vumeter.
Regards,
Mark Blofeld
VCV Rack v 1.1.6 under Windows 10.0.18363 on Intel i7-7700HQ @2.8 GHz with 4 cores
I think it is suppose the be that way. The Manual stats:
Pair of classic waveforms
AUX: sum of two hardsync’ed waveforms, the shape of which is controlled by MORPH and detuning by HARMONICS.
As long as the two oscillators are in tune (detune=0 <=> harmonics=50%) they stay in phase and the waves perfectly cancel each other (oscillators are initialized in phase). With the slightest detune one can observe beating of the two oscillators and for a breath moment perfect cancellation occurs again and again.
However I can now verify this in hardware, since I do not have a Plaits at hand.