VITA-Group/GNT

About Cross-scene Training Setting

Closed this issue · 2 comments

Thanks for you attention. You provided training command as python3 train.py --config configs/gnt_full.txt without other arguments, but I find the default number of ray sampling is 512 in config.py, while your paper said this number is 4096 which is 8 times of default setting. Dose it mean you trained you model with 8 gpu?

Yes that is correct.

I see. Thank you!