Invalid Node Name when MAC address ends in 00
acbuynak opened this issue · 3 comments
Issue
My controller has a MAC ending of :6b:c8:00
When the motoros2_config.yaml node_name
is set to default, the last MotoROS2 app loads the last byte (00
) as a single zero with a space ( 0
)
With a default motoros2_config.yaml, this results in...
Config: node_name = 'motoman_6b_c8_ 0'
and the subsequent rclc error code (rcl codes reference)
rclc_node_init_with_options = 201
Operational Patch
My solution was to just manually configure my node_name
. This allows everything to work as expected.
State of system which produced issue
MotoROS2 v0.1.1
Hardware
YRC1000
Controller Version: YAS4.73.00A
Robot. 1 x GP20HL
Error on Teach Pendant:
ALARM 8011 - MotoROS2: Fatal Error [5]
Files
1 - 20230901T210604_motoros2_debug_log.txt
2 - micro_ros_terminal_output.txt
3 - PANELBOX.LOG
Thanks for reporting this @acbuynak. And thank you for the clear bug report.
I've opened #145 with what I believe would be the fix.
Realizing this could be related to #55?
The MAC of that controller does contain a zero in the third octet (client key is based on the MAC and is: 0x790A375F
). That would indeed be formatted as A
, just as in your case.
Added YRC labels as well as this issue is not specific to any controller version.