Invalid PRV02 code in 2310B

Closed this issue · 1 comments

There is a PVR02 element error in map 837.5010.X222.A1.xml. If the 2310B loop is parented to a 2000B loop then the valid code for the PVR02 element is correct - 'PXC' - line 5166. But, if the 2310B is parented to a 2000C loop, then the PVR02 element has a valid code listed as 'ZZ' at line 15719. That is the old code from 4010A1. It should also be 'PXC'.

Thanks and sorry to be a pest.

Not a problem - glad to have the help.

Just pushed the fix.