cicwi/flexTOMO

astra-toolbox 1.9.9 breaks flextomo

Opened this issue · 2 comments

wjp commented

Probably due to output rescaling.

wjp commented

_bp_norm_ needs updating (and also _forwardprojector_norm_, _backprojector_norm_)

wjp commented

Strongly related issue: the factor 2 in the update step in l2_update is sometimes too big if the bp_weight factor is also overestimated, and can cause divergence.