clinicalml/cfrnet

Reported results

Opened this issue · 1 comments

Hi,

I ran the simulation using the provided configuration and observed results that appear to differ from the results reported in your paper. Despite my efforts to investigate the cause of this discrepancy, I have been unable to determine why these results differ.

I have used the following configuration:

p_alpha=[0.3]
p_lambda=[1e-4]
n_in=[3]
n_out=[3]
nonlin='elu'
lrate=[1e-3]
batch_size=[100]
dim_in=[200]
dim_out=[100]
batch_norm=[0]
normalization=['divide']
imb_fun=['wass']
experiments=1000
reweight_sample=[1]
split_output=[1]
rep_weight_decay=[0]
dropout_in=1.0
dropout_out=1.0
rbf_sigma=0.1
lrate_decay=0.97
decay=0.3
optimizer='Adam'
wass_lambda=10.0
wass_iterations=10
wass_bpt=1
use_p_correction=0
iterations=3000
weight_init=[0.1]
outdir='results/example_ihdp'
datadir='data/'
dataform='ihdp_npci_1-1000.train.npz'
data_test='ihdp_npci_1-1000.test.npz'
pred_output_delay=200
loss='l2'
sparse=0
varsel=0
repetitions=1
val_part=0.3

and I got the following results:

Mode: Train
| Pehe | Bias_ate | Rmse_fact | Rmse_cfact | Rmse_ite | Objective | Pehe_nn

0 | 0.785 +/- 0.052 | 0.219 +/- 0.031 | 1.135 +/- 0.045 | 1.188 +/- 0.020 | 1.164 +/- 0.021 | 0.994 +/- 0.036 | 4.895 +/- 0.613

Mode: Valid
| Pehe | Bias_ate | Rmse_fact | Rmse_cfact | Rmse_ite | Objective | Pehe_nn

0 | 0.884 +/- 0.084 | 0.224 +/- 0.031 | 1.363 +/- 0.091 | 1.206 +/- 0.032 | 1.201 +/- 0.032 | 1.995 +/- 0.402 | 5.661 +/- 0.799

Mode: Test
| Pehe | Bias_ate | Rmse_fact | Rmse_cfact | Rmse_ite | Pehe_nn

0 | 0.833 +/- 0.056 | 0.236 +/- 0.032 | 1.287 +/- 0.065 | 1.182 +/- 0.024 | 1.183 +/- 0.022 | 5.456 +/- 0.682

Thank you for your attention to this matter, and I look forward to your response.

我也出现了这种情况