Sensor and switch doesn't update (regression)
sveinse opened this issue · 4 comments
The zaptec_charger_*
sensor and the zaptec_*_switch
are extremely slow to update its state, maybe not at all. I waited over 2 hours and the field doesn't update without restarting. The previous version was immediate.
Technically they use the attribute operating_mode
, which comes from the (static?) attrs read from the API at build. The previous implementation used charger_operation_mode
, which is read from state (stateID 710) and thus updated. Might the problem here be that the latter is updated on the event notifications, while the former is not?
That might be the case. Can you a dump from using the API to show what attributes you have available for your charger?
You can find a redacted data dump from the API here: https://gist.github.com/sveinse/6b59a2b4236cd2ccf561646e889465d6 - each redaction are numbered, so you can cross correlate them
This is fixed in v0.7.0. Closing issue