Add descriptions of expected output in .bed files
Opened this issue · 1 comments
kkowalden commented
Hello,
I'm using your tool to evaluate assemblies produced with PacBio HiFi reads, 10x reads, and Omni-C reads.
Can you provide descriptions of the expected output columns in the various bed files?
My final punchlist bed file has only "C"s present in the final column, which I assume means "conflict". I don't have any "S", which I'm assuming means "supported".
If I knew what the upstream file fields are, I can possibly troubleshoot there.
Thanks!
Kim
dfguan commented
Hi Kim,
C means a mis-assembled contig sequence, while S represents a mis-assembled join, i.e. two contigs were wrongly joined.
Best,
Dengfeng.