Edit hp93k configuration files such as timing and levels in Vim. Press F8 to
send changes to the tester.
Choose a place to keep ntk.vim where it will be convenient to go back and
pull in new updates. It's not recommended to put it directly under your
.vim/plugins directory, but instead put it in a project folder and symlink.
mkdir -p ~/src
cd ~/src
git clone https://github.com/gitfoxi/ntk-vim.git
mkdir -p ~/.vim/plugins
ln -s ~/src/ntk.vim/ntk.vim ~/.vim/plugins/
When a new version is available:
cd ~/src/ntk.vim
git pull
vim timing/mydevice.tim
Make your edits then press F8 to download.
If you run under gvim, you will get an hp93k menu of available commands.
gvim levels/mydevice.lev
Under ntk.vim/myhpt you'll find two useful programs:
Sends any firmware-based file to the tester. Smart enough to not send
hp93000,config,0.1 type lines but not much smarter than that. Usage:
myhpt configuration/mydevice.conf
or
cat configuration/mydevice.conf | myhpt
The latter is convenient if you want to start using myhpt under another
program for your own evil purposes.
Wraps myhpt and adds a little smarts. Detects the file type using the
hp93000,XXX,0.1 line and sends extra firmware commands to make the loading go
smoothly. You can change it's behavior by editing files like:
- config.fw.pre -- Firmware commands to send **before** sending a config file
- config.fw.post -- Firmware commands to send **after** sending a config file
Extra smarts lets you use this to load a Pattern Master File:
send_to_mcd.py vectors/mydevice.pmf
I'm developing this with hp93k smarTest 6.5.4 under RHEL5u6 on PinScale but do aim to support other smarTest versions in the 4.x to 7.x range and platforms like C400, P600 and SmartScale . One problem that might arise with other versions of smarTest and other testers is that they might require different magic firmware incantations before and after sending a firmware file.
You should know about hpt and diag 2. If you want to see what firmware
commands should go before loading a configuration file, start logging firmware
commands:
/opt/hp93000/soc/pws/bin/hpt
task: diag 2
diag 2 starts firmware logging. Then load your configuration file. Then in at
the hpt task: prompt:
task: diag -2
diag -2 stops logging. Now open up /var/opt/hp93000/soc/MCDLog and do some
research!
In order to use ntk.vim you need Vim compiled with Python support. The default Vim on RHEL3u7 and RHEL5u7 which is the normal platform for the hp93k has this. You can check with:
vim --version | grep +python -c
If all is well it will say:
1
If it says:
0
Then you have a problem. Remember to use vim and not vi because vi starts
a retarded version of Vim.
The MIT License (MIT)
Copyright (c) 2013 Michael Fox
Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions: The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software. THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.