hristo-atanasov/Tasmota-IRHVAC

Add "Panasonic CS-E12QKEW" to compatibility List

duczz opened this issue · 2 comments

duczz commented

Hello,

you can add the "Panasonic CS-E12QKEW" to the compatibility List, its working fine with following Settings

Tasmota Log (in older tasmota versions "Model":"DKE" shows Model":3):
14:10:29.104 MQT: stat/Klimaanlage_Buero/RESULT = {"IRHVAC":{"Vendor":"PANASONIC_AC","Model":"DKE","Command":"Control","Mode":"Auto","Power":"Off","Celsius":"On","Temp":22,"FanSpeed":"Min","SwingV":"High","SwingH":"Middle","Quiet":"Off","Turbo":"On","Econo":"Off","Light":"Off","Filter":"Off","Clean":"Off","Beep":"Off","Sleep":-1,"Clock":910,"iFeel":"Off","SensorTemp":"n/a"}}

Homeasssitant Settings (i think "hvac_model: 3" ist only the important thing):

#Büro
  - platform: tasmota_irhvac
    name: "Klimaanlage Buero"
    command_topic: "cmnd/Klimaanlage_Buero/irhvac"
    # Pick one of the following:
    # State is updated when the tasmota device receives an IR signal (includes own transmission and original remote)
    # useful when a normal remote is in use alongside the tasmota device, may be less reliable than the second option.
    #state_topic: "tele/Klimaanlage_Buero/RESULT"
    # State is updated when the tasmota device completes IR transmission, should be pretty reliable.
    #state_topic: "stat/your_tasmota_device/RESULT"
    # Uncomment if your 'available topic' of Tasmota IR device are different (if device in HA is disabled)
    #availability_topic: "tele/your_tasmota_device/LWT"
    temperature_sensor: sensor.wohnzimmer_temperatursensor_snzb_02_temperature
    humidity_sensor: sensor.wohnzimmer_temperatursensor_snzb_02_humidity #optional - default None
    #power_sensor: binaly_sensor.kitchen_ac_power #optional - default None
    vendor: "PANASONIC_AC"
    min_temp: 16 #optional - default 16 int value
    max_temp: 30 #optional - default 32 int value
    target_temp: 26 #optional - default 26 int value
    initial_operation_mode: "off" # optional - default "off" string value (one of the "supported_modes")
    #away_temp: 24 #optional - default 24 int value (preset_modes)
    precision: 1 #optional - default 1 int or float value. Can be set to 1, 0.5 or 0.1
    supported_modes:
      - "auto"
      - "heat"
      - "cool"
      - "dry"
      - "fan_only" # Use "fan_only" even if Tasmota shows "Mode":"Fan"
      - "off" #Turns the AC off - Should be in quotes
      # Some devices have "auto" and "fan_only" switched. If the following two lines are uncommented, "auto" and "fan" shoud be commented out
      #- "auto_fan_only" #if remote shows fan but tasmota says auto
      #- "fan_only_auto" #if remote shows auto but tasmota says fan
    supported_fan_speeds:
      # Some devices say max,but it is high, and auto which is max. If you uncomment the following two, you have to comment high and max
      # - "auto_max" #woud become max
      # - "max_high" #would become high
      #- "on"
      #- "off"
      - "auto"
      - "min"
      - "low"
      - "medium"
      - "high"
      - "max"
    supported_swing_list:
      - "off"
      - "vertical" #up to down
      - "horizontal" # Left to right
      #- "both"
    default_quiet_mode: "Off" #Quiet und Turbo sind in der Firmware vertauscht | optional - default "Off" string value
    default_turbo_mode: "On" #Quiet und Turbo sind in der Firmware vertauscht | optional - default "Off" string value
    default_econo_mode: "Off" #optional - default "Off" string value
    hvac_model: "3" #optional - default "1" string value
    celsius_mode: "On" #optional - default "On" string value
    default_light_mode: "Off" #optional - default "Off" string value
    default_filter_mode: "Off" #optional - default "Off" string value
    default_clean_mode: "Off" #optional - default "Off" string value
    default_beep_mode: "Off" #optional - default "Off" string value
    default_sleep_mode: "-1" #optional - default "-1" string value
    default_swingv: "high" #optional - default "" string value
    default_swingh: "middle" #optional - default "" string value 
    keep_mode_when_off: True #optional - default False boolean value : Must be True for MITSUBISHI_AC, ECOCLIM, etc.

It is good to know that you've foound a way to made it work for you. Anyway, we don't have official list of supported brands and models. We are using IRremoteESP8266 Supported Protocols page to check different brands and models compatibility, as this is the library that Tasmota is using.

duczz commented

ah okay, than i create a ticket there ;)