[BUG] Can't run it with MPV, causes the error: No option 'input-ipc-server' in section: 'root'
xcloudx01 opened this issue · 2 comments
I'm trying to install it following the guide for MPV, but after following the steps an error occurs and scrobbling does not work.
I've done "trakt init" to set it up with MPV, and "trakt test" shows a successful token. But run "trakts test mpv" and the following error occurs:
Testing connection with mpv.
Please ensure that mpv is playing some media.
Config value autoload failed for mpv.
Traceback (most recent call last):
File "C:\Users\cloud\AppData\Local\Programs\Python\Python311\Lib\configparser.py", line 805, in get
value = d[option]
~^^^^^^^^
File "C:\Users\cloud\AppData\Local\Programs\Python\Python311\Lib\collections\__init__.py", line 1004, in __getitem__
return self.__missing__(key) # support subclasses that define __missing__
^^^^^^^^^^^^^^^^^^^^^
File "C:\Users\cloud\AppData\Local\Programs\Python\Python311\Lib\collections\__init__.py", line 996, in __missing__
raise KeyError(key)
KeyError: 'input-ipc-server'
During handling of the above exception, another exception occurred:
Traceback (most recent call last):
File "C:\Users\cloud\.local\pipx\venvs\trakt-scrobbler\Lib\site-packages\trakt_scrobbler\player_monitors\monitor.py", line 82, in __new__
cls.config = cls.autoload_cfg()
^^^^^^^^^^^^^^^^^^
File "C:\Users\cloud\.local\pipx\venvs\trakt-scrobbler\Lib\site-packages\trakt_scrobbler\player_monitors\monitor.py", line 127, in autoload_cfg
monitor_cfg[param] = param_loader()
^^^^^^^^^^^^^^
File "C:\Users\cloud\.local\pipx\venvs\trakt-scrobbler\Lib\site-packages\trakt_scrobbler\player_monitors\mpv.py", line 73, in <lambda>
"ipc_path": lambda: mpv_conf.get("root", "input-ipc-server")
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "C:\Users\cloud\AppData\Local\Programs\Python\Python311\Lib\configparser.py", line 808, in get
raise NoOptionError(option, section)
configparser.NoOptionError: No option 'input-ipc-server' in section: 'root'
Could not start monitor for mpv
Hint: Try re-running trakts test with '-vvv' to enable more debug logging.
I'm on Win11.
Is there any solution? Thanks
Looks like your mpv config is a bit weird. Could you please paste it here? Please make sure that you have set the input-ipc-server
field in your mpv config as described in the setup.
Thank you! I had indeed forgotten to add the input-ipc-server field to my mpv.conf. It is working as expected now <3. Thanks again
The toast message is giving a minor error in the log whenever it pops up but it's no biggie, figured I'd paste it here for your reference if you wanted to look into it sometime:
2023-10-09 12:43:41,375 - ERROR - Thread-38 (_show_toast) - __init__ - Unhandled exception
TypeError: WPARAM is simple, so must be an int object (got NoneType)