Don´t know the Fronius API yet, but oriented on Go-E API v2 I dont understand following. May I´m wrong, but i this right?

modelStatus R uint8 Status Reason why we allow charging or not right now (NotChargingBecauseNoChargeCtrlData=0, NotChargingBecauseOvertemperature=1, NotChargingBecauseAccessControlWait=2, ChargingBecauseForceStateOn=3, NotChargingBecauseForceStateOff=4, NotChargingBecauseScheduler=5, NotChargingBecauseEnergyLimit=6, ChargingBecauseAwattarPriceLow=7, ChargingBecauseAutomaticStopTestLadung=8, ChargingBecauseAutomaticStopNotEnoughTime=9, ChargingBecauseAutomaticStop=10, ChargingBecauseAutomaticStopNoClock=11, ChargingBecausePvSurplus=12, ChargingBecauseFallbackGoEDefault=13, ChargingBecauseFallbackGoEScheduler=14, ChargingBecauseFallbackDefault=15, NotChargingBecauseFallbackGoEAwattar=16, NotChargingBecauseFallbackAwattar=17, NotChargingBecauseFallbackAutomaticStop=18, ChargingBecauseCarCompatibilityKeepAlive=19, ChargingBecauseChargePauseNotAllowed=20, NotChargingBecauseSimulateUnplugging=22, NotChargingBecausePhaseSwitch=23, NotChargingBecauseMinPauseDuration=24)
car R optional Status carState, null if internal error (Unknown/Error=0, Idle=1, Charging=2, WaitCar=3, Complete=4, Error=5)
err R optional Status error, null if internal error (None = 0, FiAc = 1, FiDc = 2, Phase = 3, Overvolt = 4, Overamp = 5, Diode = 6, PpInvalid = 7, GndInvalid = 8, ContactorStuck = 9, ContactorMiss = 10, FiUnknown = 11, Unknown = 12, Overtemp = 13, NoComm = 14, StatusLockStuckOpen = 15, StatusLockStuckLocked = 16, Reserved20 = 20, Reserved21 = 21, Reserved22 = 22, Reserved23 = 23, Reserved24 = 24)

carValues[1] = "no car"

errValues[0] = "Unknown Error"

Is this right or are there things mixed up?

"err" -> "errorState" -> should be:
error, null if internal error (None = 0, FiAc = 1, FiDc = 2, Phase = 3, Overvolt = 4, Overamp = 5, Diode = 6, PpInvalid = 7, GndInvalid = 8, ContactorStuck = 9, ContactorMiss = 10, FiUnknown = 11, Unknown = 12, Overtemp = 13, NoComm = 14, StatusLockStuckOpen = 15, StatusLockStuckLocked = 16, Reserved20 = 20, Reserved21 = 21, Reserved22 = 22, Reserved23 = 23, Reserved24 = 24)
"car" -> (Unknown/Error=0, Idle=1, Charging=2, WaitCar=3, Complete=4, Error=5) 0 and 5 is missing
1 -> No Car
2 -> Charging
3 -> Wait for car allows
4 -> Complete

ChargingState -> ModelState ?

May this would better fit?

Thx!

most likely the go-e API is correct. go-e API Description did not contain the description for err and car properties and the values in the sourcecode were guessed and taken from the older API Description (just realised go-e updated the description a few days ago).
I will update the properties in the source.

Perfect! Thx!

Is there in between an api description for Fronius Wattpilot? I will bother them on the fair InterSolar in May...;-)

No as Fronius Wattpilot does not even have an "open" API, but the software of the wattpilot seems to have a similar codebase as the e-go chargers and the information from e-go API Description most likely fits to 95% for the wattpilot (at least the properties). There is a property (pck) in the API which seems to include the software-modules of the wallbox. It includes a froniusinverter module (for PV excess charging) but no API module on the wattpilot.
I do not know if the reason for the missing API is a business decision by Fronius (closed "fronius" ecosystem, lesser licensecosts,...) or e-go (keeping a sellingpoint for e-go charger against wattpilot) or a technical decision, as the capacity of the microcontroller might be the limiting factor and they needed the space to add the froniusinverter code.

@joscha82, @thecem maybe you are interested in this PR which besides full Home Assistant support introduces value maps in wattpilot.yaml to provide human-readable values instead of plain integers: #9