Cooling compensation curve: wrong min/max values
Closed this issue · 0 comments
** Versions **
- Home Assistant version (for instance 2023.9): 2024.06
- This integration version (for instance 1.1.0): 1.9.0
Describe the bug
Hi,
the min/max values for the entities regarding cooling compensation curve seem to be wrong.
On my heat pump (Aquarea L series 5kw), setting everything to min/max looks like this:
However, the temperature range I can set in this integration is:
Min and max outside temperature: -20°C to 30°C
Min/max water temperature: 15°C to 60°C
I suppose having larger range (as with the outside temperature) is not beautiful, but not really a problem.
However, only being able to set the min water temperature to 15°C is a bit lacking - in some cases I want to set it lower than that.
To Reproduce
Steps to reproduce the behavior:
Slightly adapted your Heat curve adjustment card to make it easy to test:
type: vertical-stack
title: Kühlkurve
cards:
- type: vertical-stack
cards:
- type: horizontal-stack
cards:
- type: entities
entities:
- entity: number.panasonic_heat_pump_main_z1_cool_curve_outside_low_temp
- entity: number.panasonic_heat_pump_main_z1_cool_curve_target_high_temp
- type: horizontal-stack
cards:
- type: entities
entities:
- entity: >-
number.panasonic_heat_pump_main_z1_cool_curve_outside_high_temp
- entity: number.panasonic_heat_pump_main_z1_cool_curve_target_low_temp
- type: custom:plotly-graph
refresh_interval: 10
defaults:
entity:
show_value: true
line:
shape: spline
layout:
xaxis:
type: number
autorange: true
entities:
- entity: ''
name: Zone 1
x:
- >-
$ex
hass.states['number.panasonic_heat_pump_main_z1_cool_curve_outside_low_temp'].state
- >-
$ex
hass.states['number.panasonic_heat_pump_main_z1_cool_curve_outside_high_temp'].state
'y':
- >-
$ex
hass.states['number.panasonic_heat_pump_main_z1_cool_curve_target_high_temp'].state
- >-
$ex
hass.states['number.panasonic_heat_pump_main_z1_cool_curve_target_low_temp'].state
Expected behavior
It should be possible to set it lower than 15°C