Crash Program - Regione Molise - UC1 - Richiesta chiarimenti
Closed this issue · 10 comments
Salve, si é provveduto ad inviare un referto al gateway ottenendo come response
`HTTP/1.1 201 Created
X-Backside-Transport: OK OK
Connection: Keep-Alive
Transfer-Encoding: chunked
Expires: 0
Cache-Control: no-cache, no-store, must-revalidate
set-cookie: 894d46ecfc124039ee218b63c12a3329=9c62788caf0fe4a977db8e11a8d1653d; path=/; HttpOnly; Secure; SameSite=None
Server: GovWay-SOGEI
Pragma: no-cache
GovWay-Message-ID: 549349d6-9cce-4da7-9274-180a9db2039f
GovWay-Transaction-ID: 303ed310-7a84-11ef-b8bd-005056ae54fa
server-timing: intid;desc=e085826d76c19a1b
Date: Tue, 24 Sep 2024 14:56:24 GMT
Vary: *
X-Content-Type-Options: nosniff
Content-Type: application/json
X-Global-Transaction-ID: 6026e6bc66f2d317898c5b8f
{"traceID":"b8b62ce25407f5f4","spanID":"b8b62ce25407f5f4","workflowInstanceId":"2.16.840.1.113883.2.9.2.140.4.4.82683c378e3c77e42839bf1f447eea9bb923f34043f95f6521f51f500d33daf1.fa7e138c15^^^^urn:ihe:iti:xdw:2013:workflowInstanceId"}
`
Si rileva che non é stata ricevuta la comunicazione metadati per tramite di INI,
ed effettuando il getStatus si é ottenuto il response
{ "traceID": "3701117826105b8d", "spanID": "f2c98835ebd18d01", "transactionData": [ { "eventType": "VALIDATION_FOR_PUBLICATION", "eventDate": "2024-09-24T14:56:24.348+00:00", "eventStatus": "SUCCESS", "subject": "PRSTZN75L52B519D^^^&2.16.840.1.113883.2.9.4.3.2&ISO", "organizzazione": "140", "workflowInstanceId": "2.16.840.1.113883.2.9.2.140.4.4.82683c378e3c77e42839bf1f447eea9bb923f34043f95f6521f51f500d33daf1.fa7e138c15^^^^urn:ihe:iti:xdw:2013:workflowInstanceId", "traceId": "b8b62ce25407f5f4", "issuer": "integrity:S1#111ENGINNERING", "expiringDate": "2025-09-24T14:56:24.360+00:00" }, { "eventType": "PUBLICATION", "eventDate": "2024-09-24T14:56:24.550+00:00", "eventStatus": "SUCCESS", "identificativoDocumento": "2.16.840.1.113883.2.9.2.140.4.4^ELIOT_202478965_1727188682402", "subject": "PRSTZN75L52B519D^^^&2.16.840.1.113883.2.9.4.3.2&ISO", "tipoAttivita": "DIS", "organizzazione": "140", "workflowInstanceId": "2.16.840.1.113883.2.9.2.140.4.4.82683c378e3c77e42839bf1f447eea9bb923f34043f95f6521f51f500d33daf1.fa7e138c15^^^^urn:ihe:iti:xdw:2013:workflowInstanceId", "traceId": "b8b62ce25407f5f4", "issuer": "integrity:S1#111ENGINNERING", "expiringDate": "2025-09-24T14:56:24.559+00:00" }, { "eventType": "SEND_TO_INI", "eventDate": "2024-09-24T14:56:24.615+00:00", "eventStatus": "SUCCESS", "message": "Regime di mock abilitato", "workflowInstanceId": "2.16.840.1.113883.2.9.2.140.4.4.82683c378e3c77e42839bf1f447eea9bb923f34043f95f6521f51f500d33daf1.fa7e138c15^^^^urn:ihe:iti:xdw:2013:workflowInstanceId", "expiringDate": "2025-09-24T14:56:24.678+00:00" } ] }
In particolare si richiede il significato del messaggio "Regime di mock abilitato" per l'event SEND_TO_INI,
da specifiche ci saremmo aspettati di ricevere i metadati direttamente da INI.
Grazie mille
Buongiorno,
le chiediamo se sta utilizzando i certificati ricevuti per il Crash Program.
In caso contrario, la invitiamo a riprovare impiegando i certificati corretti.
Qualora non li avesse richiesti, per ottenerli può seguire la procedura descritta in documentazione al link: https://ministero-salute.github.io/it-fse-support/crashprogram/
Grazie.
Salve,
stamattina è stato effettuato un nuovo test con i certificati ricevuti per il Crash Program,
la validazione ha avuto esito positivo, relativamente al
workflowInstanceId": "2.16.840.1.113883.2.9.2.140.4.4.82683c378e3c77e42839bf1f447eea9bb923f34043f95f6521f51f500d33daf1.1bc6d52348^^^^urn:ihe:iti:xdw:2013:workflowInstanceId
ed anche il passo di create ha avuto esito positivo, relativamente al "traceID":"cefe5165e79a1fd2"
Ma effettuando la chiamata alla funzione status/{workflowInstanceId}, si riscontra un errore nell'evento "SEND_TO_INI", che qui riporto:
{ "eventType": "SEND_TO_INI", "eventDate": "2024-09-25T10:29:54.745+00:00", "eventStatus": "BLOCKING_ERROR", "message": "500 : \"{\"traceID\":\"1810731849247dac\",\"spanID\":\"1810731849247dac\",\"type\":\"/errors\",\"title\":\"Generic\",\"detail\":\"com.sun.xml.ws.fault.ServerSOAPFaultException: Client received SOAP Fault from server: Patient validation error Please see the server log to find more detail regarding exact cause of the failure.\",\"instance\":\"error/generic\"}\"", "workflowInstanceId": "2.16.840.1.113883.2.9.2.140.4.4.82683c378e3c77e42839bf1f447eea9bb923f34043f95f6521f51f500d33daf1.1bc6d52348^^^^urn:ihe:iti:xdw:2013:workflowInstanceId", "expiringDate": "2025-09-25T10:29:54.755+00:00" }
Il paziente utilizzato era uno dei due concordati per il Crash Program.
Potreste cortesemente darci un supporto?
Grazie mille
Buonasera,
potrebbe gentilmente riprovare?
Rimaniamo a disposizione nel caso in cui riscontrasse altri problemi.
Grazie.
Salve.
Riprovando si ha lo stesso errore.
{ "eventType": "SEND_TO_INI", "eventDate": "2024-09-25T14:24:17.255+00:00", "eventStatus": "BLOCKING_ERROR", "message": "500 : \"{\"traceID\":\"f9f05af58c231c5c\",\"spanID\":\"f9f05af58c231c5c\",\"type\":\"/errors\",\"title\":\"Generic\",\"detail\":\"com.sun.xml.ws.fault.ServerSOAPFaultException: Client received SOAP Fault from server: Patient validation error Please see the server log to find more detail regarding exact cause of the failure.\",\"instance\":\"error/generic\"}\"", "workflowInstanceId": "2.16.840.1.113883.2.9.2.140.4.4.580867f1f583572c016763cffae448c86a2140ab6cb7e8f921db567f587160fc.d4194c1d9e^^^^urn:ihe:iti:xdw:2013:workflowInstanceId", "expiringDate": "2025-09-25T14:24:17.319+00:00" }
Ciao @marlagatta,
mi scuso per l'intromissione, ma il titolo dell'issue ha catturato la mia attenzione.
Vorremmo attivare la pubblicazione di referti lab/rad in Regione Molise per i clienti accreditati al SSN. Potrebbe fornirmi le specifiche di integrazione o un contatto a cui fare richiesta?
Buonasera,
ieri ci sono stati disservizi sul nostro ambiente. Vi chiedo di riprovare.
In caso di errore, vi chiedo pure di indicarci CF dell'assistito utilizzato e il timestamp del tentativo.
Ciao @marlagatta,
mi scuso per l'intromissione, ma il titolo dell'issue ha catturato la mia attenzione.
Vorremmo attivare la pubblicazione di referti lab/rad in Regione Molise per i clienti accreditati al SSN. Potrebbe fornirmi le specifiche di integrazione o un contatto a cui fare richiesta?
Ho già scritto a fse@regione.molise.it, ma non ho ricevuto risposta.
Salve,
la invito a contattare il direttore dei lavori FSE, ing. Nicola Zappone alla mail nicola.zappone@molisedati.it
Buonasera, ieri ci sono stati disservizi sul nostro ambiente. Vi chiedo di riprovare. In caso di errore, vi chiedo pure di indicarci CF dell'assistito utilizzato e il timestamp del tentativo.
Spiacente, il problema persiste
{ "eventType": "SEND_TO_INI", "eventDate": "2024-09-26T14:15:33.565+00:00", "eventStatus": "BLOCKING_ERROR", "message": "500 : \"{\"traceID\":\"967a20c370945fe2\",\"spanID\":\"967a20c370945fe2\",\"type\":\"/errors\",\"title\":\"Generic\",\"detail\":\"com.sun.xml.ws.fault.ServerSOAPFaultException: Client received SOAP Fault from server: Patient validation error Please see the server log to find more detail regarding exact cause of the failure.\",\"instance\":\"error/generic\"}\"", "workflowInstanceId": "2.16.840.1.113883.2.9.2.140.4.4.cac7018afde5340e6af12fb67f6956f500b8ef1d2faace003f85457454573190.ac8f3b171e^^^^urn:ihe:iti:xdw:2013:workflowInstanceId", "expiringDate": "2025-09-26T14:15:33.632+00:00" }
Il codice fiscale del paziente e' `ZCCSBT75C05I282D`
L'invio e' stato effettuato il 26-09-2024 16:15:32.262
la risposta ricevuta alle 26-09-2024 16:15:33.476
L'evento "SEND_TO_INI" corrisponde all "eventDate": "2024-09-26T14:15:33.565+00:00"
Grazie mille
Salve.
Riprovando oggi il caso di test per lo stesso paziente, la pubblicazione ha avuto di nuovo esito positivo, ma l'evento SEND_TO_INI ha restituito nuovamente l'errore boccante riscontrato il 25 settembre scorso,
{ "eventType": "SEND_TO_INI", "eventDate": "2024-09-30T12:26:39.959+00:00", "eventStatus": "BLOCKING_ERROR", "message": "500 : \"{\"traceID\":\"8e6e20904244e017\",\"spanID\":\"8e6e20904244e017\",\"type\":\"/errors\",\"title\":\"Generic\",\"detail\":\"com.sun.xml.ws.fault.ServerSOAPFaultException: Client received SOAP Fault from server: Patient validation error Please see the server log to find more detail regarding exact cause of the failure.\",\"instance\":\"error/generic\"}\"", "workflowInstanceId": "2.16.840.1.113883.2.9.2.140.4.4.d4451f2d3ae9f6536514548d3dc9cabb1cf0d58015695ebb1b7c39d2c094ec09.bacee4ee52^^^^urn:ihe:iti:xdw:2013:workflowInstanceId", "expiringDate": "2025-09-30T12:26:40.134+00:00" }
Potreste cortesemente assisterci nell'individuarne le cause?
Grazie mille
Buongiorno,
La informiamo che il Codice fiscale da lei indicato "ZCCSBT75C05I282D" è stato censito ed è ora possibile assegnare i consensi e procedere con una nuova prova. Grazie