Locals in FMU export reference files
Closed this issue · 3 comments
Reported by maplesoft on 30 Jan 2017 14:16 UTC
A number of exported FMUs contain data for local variables in the reference files. Since these local variables are internal to the FMU and are listed under 'protected' section during Import, the importing tools may not allow access to such variables including for the purposes of plotting. We propose that the local variables should not be included in the reference CSV files, only outputs and states.
Migrated-From: https://trac.fmi-standard.org/ticket/408
Comment by karl.wernersson on 15 Jun 2017 14:31 UTC
As the compliance checker as far as I know don't support support picking which variables to store besides output or all, it might be even better to restrict to only outputs if we are going to restrict it.
Comment by cbertsch on 1 Jun 2018 19:38 UTC
Suggested to include restriction to outputs in XC rules V4