The dell server cannot obtain related metrics such as idrac_drive, idrac_memory and idrac_sel.
ilanni2460 opened this issue · 2 comments
This is the relevant metrics captured through Prometheus:
`
HELP idrac_exporter_build_info Constant metric with build information for the exporter
TYPE idrac_exporter_build_info untyped
idrac_exporter_build_info{goversion="go1.21.3",revision="1d415e0a284d2e99b1a4e8b6adce0f779a81b7f4",version="1.0.0"} 1
HELP idrac_exporter_scrape_errors_total Total number of errors encountered while scraping target
TYPE idrac_exporter_scrape_errors_total gauge
idrac_exporter_scrape_errors_total 0
HELP idrac_power_control_avg_consumed_watts Average consumption of power control system during the reported interval
TYPE idrac_power_control_avg_consumed_watts gauge
idrac_power_control_avg_consumed_watts{id="0",name="System Power Control"} 612
HELP idrac_power_control_capacity_watts Capacity of power control system in watts
TYPE idrac_power_control_capacity_watts gauge
idrac_power_control_capacity_watts{id="0",name="System Power Control"} 2240
HELP idrac_power_control_consumed_watts Consumption of power control system in watts
TYPE idrac_power_control_consumed_watts gauge
idrac_power_control_consumed_watts{id="0",name="System Power Control"} 567
HELP idrac_power_control_interval_in_minutes Interval for measurements of power control system
TYPE idrac_power_control_interval_in_minutes gauge
idrac_power_control_interval_in_minutes{id="0",name="System Power Control"} 1
HELP idrac_power_control_max_consumed_watts Maximum consumption of power control system during the reported interval
TYPE idrac_power_control_max_consumed_watts gauge
idrac_power_control_max_consumed_watts{id="0",name="System Power Control"} 1002
HELP idrac_power_control_min_consumed_watts Minimum consumption of power control system during the reported interval
TYPE idrac_power_control_min_consumed_watts gauge
idrac_power_control_min_consumed_watts{id="0",name="System Power Control"} 544
HELP idrac_power_supply_capacity_watts Power supply capacity in watts
TYPE idrac_power_supply_capacity_watts gauge
idrac_power_supply_capacity_watts{id="0"} 1600
idrac_power_supply_capacity_watts{id="1"} 1600
HELP idrac_power_supply_efficiency_percent Power supply efficiency in percentage
TYPE idrac_power_supply_efficiency_percent gauge
idrac_power_supply_efficiency_percent{id="0"} 91.0000026226044
idrac_power_supply_efficiency_percent{id="1"} 91.0000026226044
HELP idrac_power_supply_input_voltage Power supply input voltage
TYPE idrac_power_supply_input_voltage gauge
idrac_power_supply_input_voltage{id="0"} 220
idrac_power_supply_input_voltage{id="1"} 220
HELP idrac_power_supply_input_watts Power supply input in watts
TYPE idrac_power_supply_input_watts gauge
idrac_power_supply_input_watts{id="0"} 550
idrac_power_supply_input_watts{id="1"} 5
HELP idrac_power_supply_output_watts Power supply output in watts
TYPE idrac_power_supply_output_watts gauge
idrac_power_supply_output_watts{id="0"} 516
idrac_power_supply_output_watts{id="1"} 0
HELP idrac_sensors_fan_speed Sensors reporting fan speed measurements
TYPE idrac_sensors_fan_speed gauge
idrac_sensors_fan_speed{id="0",name="System Board Fan1",units="rpm"} 7320
idrac_sensors_fan_speed{id="1",name="System Board Fan2",units="rpm"} 7320
idrac_sensors_fan_speed{id="2",name="System Board Fan3",units="rpm"} 7320
idrac_sensors_fan_speed{id="3",name="System Board Fan4",units="rpm"} 7320
idrac_sensors_fan_speed{id="4",name="System Board Fan5",units="rpm"} 7200
idrac_sensors_fan_speed{id="5",name="System Board Fan6",units="rpm"} 7200
idrac_sensors_fan_speed{id="6",name="System Board Fan7",units="rpm"} 7320
idrac_sensors_fan_speed{id="7",name="System Board Fan8",units="rpm"} 7200
HELP idrac_sensors_temperature Sensors reporting temperature measurements
TYPE idrac_sensors_temperature gauge
idrac_sensors_temperature{id="0",name="CPU1 Temp",units="celsius"} 58
idrac_sensors_temperature{id="1",name="CPU2 Temp",units="celsius"} 50
idrac_sensors_temperature{id="2",name="System Board Inlet Temp",units="celsius"} 23
idrac_sensors_temperature{id="3",name="CPU3 Temp",units="celsius"} 58
idrac_sensors_temperature{id="4",name="CPU4 Temp",units="celsius"} 49
idrac_sensors_temperature{id="5",name="System Board Exhaust Temp",units="celsius"} 33
HELP idrac_system_bios_info Information about the BIOS
TYPE idrac_system_bios_info untyped
idrac_system_bios_info{version="2.11.2"} 1
HELP idrac_system_cpu_count Total number of CPUs in the system
TYPE idrac_system_cpu_count gauge
idrac_system_cpu_count{model="Intel(R) Xeon(R) Gold 6254 CPU @ 3.10GHz"} 4
HELP idrac_system_health Health status of the system
TYPE idrac_system_health gauge
idrac_system_health{status="OK"} 0
HELP idrac_system_indicator_led_on Indicator LED state of the system
TYPE idrac_system_indicator_led_on gauge
idrac_system_indicator_led_on{state="Lit"} 1
HELP idrac_system_machine_info Information about the machine
TYPE idrac_system_machine_info untyped
idrac_system_machine_info{manufacturer="Dell Inc.",model="PowerEdge R940",serial="XXXXXXX",sku="XXXXX"} 1
HELP idrac_system_memory_size_bytes Total memory size of the system in bytes
TYPE idrac_system_memory_size_bytes gauge
idrac_system_memory_size_bytes 5.49755813888e+11
HELP idrac_system_power_on Power state of the system
TYPE idrac_system_power_on gauge
idrac_system_power_on 1
`
It's because my configuration file didn't enable these monitoring items.
address: 0.0.0.0 port: 9348 timeout: 10 retries: 1 hosts: default: username: XXXX password: XXXX metrics: system: true sensors: true power: true sel: true storage: true memory: true