[Bug]: Loading old isa.assay/study.xlsx files doesn't convert Input/Output column
caroott opened this issue · 5 comments
Contact Details
No response
What happened?
Importing an old assay or study file with an Input or Output that doesn't fit a name from this list:
just imports the column without adding Input[ ] or Output[ ] around the name and doesn't throw an error that input or output is missing.
What did you expect?
I expected that swate wraps the first and last column in Input[ ] / Output[ ] or throws an error if either one is missing.
Host
Standalone
Host Details
OS: Windows 11
Browser: Firefox Version 122.0.1 (64 Bit)
Swate version
Swate Release Version v1.0.0-alpha.12
@HLWeil I thought we had support for old input/output columns? Or was this removed for performance reasons?
What exactly is written in the old input/output column? We are catching all headers written here with deprecation handling:
The old output column was "Data File Name"
And what about input? was the input correctly read?
The input was "Source Name" and was correctly read and converted to "Input [Source Name]"