openpharma/mmrm

Swapped definition of CR2 and CR3 for vcov in the manual

Closed this issue · 2 comments

I think the definitions of covariance estimator type are swapped:

Allowed vcov includes: "Asymptotic", "Kenward-Roger", "Kenward-Roger-Linear", "Empirical" (CR0), "Empirical-Jackknife" (CR2), and "Empirical-Bias-Reduced" (CR3).

CR2 is the bias-reduced (linearization) by Pustejovsky-Tipton,
and CR3 is the leave 1 cluster out (jacknife)

package version: 0.3.5.9002
also in the CRAN version (0.3.6): https://cran.r-project.org/web/packages/mmrm/mmrm.pdf

Thanks @Generalized , @clarkliming can you maybe have a look?

thank you @Generalized . indeed in the this doc they are swapped. In the vignettes it is ok