Hi, I did some testing on a TS-65a Meter

My setup was
A Meter and conditions readout via ESP Home,
Then I tried different loads to figure out the missing registers,

My loads

  • 60W Light bulb (Resistive Load)
  • 600W VacumCleaner (Inductive Load)

With the test, I Figured out that
I'm pretty certain that this is 262..263 is PowerReal_P_Sum - 0.1W.

About 90% certain that 268..269 - Power Factor Sum - 0.001deg

And this 270..271 read always zero. So I have no Clue, maybe - Current_AC_Sum -

otti commented

I have updated the register description.