revk/SolarSystem

Abloy EL56X working

Closed this issue · 3 comments

revk commented

Unlike V lock, and mag locks, the working is not the same.

  1. The bolt in and deadlock signals only activate once the handle is used, so the logic for waiting time for them to unlock is not sensible. Can we make the system handle this directly or as a configurable setting relating to the lock disengage time? It needs to consider this not a fault (when does not appear to unlock yet), but obviously pick up a bolt out when door open as an issue non the less, and door force scenarios even if that also shows bolt in.

  2. The handle and key used signals need to be available to inhibit a door forced scenario, but we cannot expect them to immediately signal, i.e. before the door opens or lock disengages.

revk commented

Logic for door is setting -1 for lock time (when sends an explicit 0 for lock time rather than using default).

revk commented

Manual mode is part of #175

revk commented

Manual input is now deployed, even though other inputs are still old format.