Issues
- 6
Archive old dcm2niix repository?
#865 opened by DimitriPapadopoulos - 3
Troubleshooting incorrect import behavior
#862 opened by annchenknodt - 0
Antipodally reflected bvecs for sagittal DWIs
#863 opened by Lestropie - 0
PR813 issues
#861 opened by neurolabusc - 4
SIEMENS XA50 DIFFUSION DATA
#860 opened by jim-uofu - 0
Add github pages demo for dcm2niix WASM with Niivue
#859 opened by hanayik - 2
segmentation fault on s390x systems (big endian)
#854 opened by emollier - 1
Error in Mediso Dynamic PET Conversion
#853 opened by QinQikai - 8
XA-series missing minor version tracking in sidecar
#848 opened by bpinsard - 4
Addition of MAGNITUDE to ImageType of Siemens data
#851 opened by mharms - 4
- 6
- 14
Philips isotropic DWI b50 not recognized
#827 opened by JanOP1337 - 1
Different study/data time, -m option not working
#846 opened by javijv4 - 1
Feature request: Instead of providing a source directory, would it be possible to provide dcm2niix a list of files to be processed?
#840 opened by BlakeGFitch - 5
Problems with b2500 and b700 dwi data
#837 opened by stremblay18 - 4
- 2
- 2
Siemens XA60 conversion of diffusion data
#819 opened by jonbpanda - 4
PyPI missing releases newer than v1.0.20220715
#829 opened by ericearl - 2
How sform is calculate?
#828 opened by BrunoFFPP - 1
Suppress ROI1, ROI2, etc. in conversion
#832 opened by halfSpinDoctor - 3
- 0
GE slice timing error
#838 opened by neurolabusc - 5
Failed conversion with Error: Check sorted order: 4D dataset has 1 volumes, but volume index ranges from 1..###
#830 opened by ericearl - 4
Add Return Codes other than 0
#834 opened by toomanycats - 2
git clone failure?
#835 opened by marcelzwiers - 7
What is `offset` and `Valid 0`
#831 opened by toomanycats - 9
RepetitionTime is sometimes incorrectly calculated
#825 opened by lsaca05 - 12
- 3
How does dcm2niix determine SBREF dicom files?
#816 opened by John-Chin - 3
-x flag not working on PAR file
#818 opened by madeleinebarter - 1
Incorrect output files name for a duel echo image.
#821 opened by MRIDude - 3
- 0
multi-echo data not recognised
#820 opened by marcelzwiers - 2
[Question] Image dimensions from the tags
#817 opened by nilgoyette - 11
Incorrect Slice/Vol Order After Site Updated Philips Software (Ingenia version 11.1)
#809 opened by wtmccuddy - 12
PET json information
#802 opened by MarDos1234 - 16
Possible incorrect SliceTiming
#797 opened by po09i - 6
GE AcquisitionDuration
#808 opened by mr-jaemin - 2
Siemens conversion problems (Magnetom Altea)
#799 opened by ClimbMount - 1
dcm2niix is incorrectly attempting to use a JPEG:Lossless transfer syntax that was set inside an Original Attributes Sequence
#807 opened by captainnova - 2
Slice timing missing in the json file
#793 opened by xileniu - 4
Inquiry on DICOM to NIfTi
#803 opened by mikaelhaji - 1
error dcm2niix using dcm2bids
#801 opened by dbg0899 - 2
Siemens 2D epi TR is incorrect
#806 opened by pollaro - 5
GE UHP/7T Diffusion SliceTiming
#796 opened by mr-jaemin - 10
Filename oddity in 20240202 for Philips DWI
#795 opened by captainnova - 6
Q about where json gets written
#794 opened by mharms - 4
setBidsGE fails to recognize Gradient Echo EPI
#790 opened by mr-jaemin