strange result about the estimated cross-coalescence rate
liuqi-C opened this issue · 1 comments
liuqi-C commented
When I use MSMC2 (msmc_v2.1.4) to calculate the cross-coalescence rate with different time segment setting, I get some strange result, shown as follow.
- --quantileBoundaries -p 10*1+15*2
- -p 1*4+25*2+1*4+1*6
- default setting. This result seems like the correct result, but the time interval is too little before 10000 years ago, only 4 time intervals.
How can I get a correct result?
stschiff commented
Well, the first analysis just has some bizarre blow-up effect in a time-window, which doesn't look good. If you plot it on a scale from 0 to 1 you should probably get something that looks a bit like the other two plots.