Phasor card reactivemicro issue on stereo
Closed this issue · 7 comments
Hi,
I have a stereo issue on IIe (enh), the reactivemicro phazor card gives me the following result with mb-audit .
$00 = 1 in slot 4 $80 nothing SP nothing 65C02 detected.
Original reference of the issue :
a2-4am/4cade#538
From the mb-audit (v0.9) screen output, it's not detecting the 6522 at $C480 - it should show at least a "?" symbol.
Can you try swapping the 6522 chips and see if mb-audit gives you a different output?
EG, (after swapping chips) if the 6522 is faulty, then I'd expect something to now show on row "$80"...
mb-audit v0.9, Tom Charlesworth, 2021
1 2 3 4 5 6 7
$00:
$80: ?
SP:
65C02 detected
I did the swap of the Two 6522 but I get this output two ?
In this photo (from 2 days ago), the mb-audit code is hanging - because you don't get to the Slot #4 :Press CTRL+RESET ...
line.
Second test after swapping the 6522s, I just push a little bit all the chipsets.
Third test I re swap to originel position the 6522s.
But in these two photos from today, you get the same result for both swapped & not swapped 6522 chips.
So this implies to me that there's a problem with the card's socket (or connection) for this first 6522 socket. (And hopefully the 6522 chips are okay, but I can't say for sure.)
I suggest you contact ReactiveMicro and ask Henry if he can offer a replacement.
btw, I have given him mb-audit, and I think he is now using it to test his cards. So you can explain to him that mb-audit indicates a fault.
For information, Re active micro sent me a new phasor card and no more issues ! the previous card had one 6522 chips KO !
Thanks for your help to debug my card.
Thanks !
That's good news. Glad you got it sorted out.