Saj inverter R5 not giving data

Closed this issue · 2 comments

Hello, i'm trying to do a read of the rs485 port on the saj r5 inverter but dont get data, i wired the cable like you show in your image, their is a lot i can configur in the converter i'm using maybe i have a config issue. I use the USR-Tcp232-410s and it supports rs232, rs485 modbus rtu to modbus tcp.

Any advice?

Thanks anyway for this post .

Just found the issue, i used the wrong modbus adres, now i receive data from the i verter.

I just have another question, i also have a saj battery, in the documentation of the inverter i cant c anything about battery power. Do you have any info about this?

wimb0 commented

Good to hear you got it solved.
I do not have any info about the saj battery, thus I cannot help you with that.