multiple template switching oligos?
onecarbon opened this issue · 2 comments
onecarbon commented
Hi
Thanks for this - I am interested in trying it out! Could you clarify the reason for the multiple template switching oligos in this version of the protocol? It looks like the published versions have only one? Are all three now recommended?
Thanks
z0on commented
Hello! Three oligos are needed to diversify base composition near beginning of the read, which is very important for latest models of illumina sequencers.
iPhone. Apologies for brevity
… On Nov 5, 2019, at 4:21 PM, finnhamilton ***@***.***> wrote:
Hi
Thanks for this - I am interested in trying it out! Could you clarify the reason for the multiple template switching oligos in this version of the protocol? It looks like the published versions have only one? Are all three now recommended?
Thanks
—
You are receiving this because you are subscribed to this thread.
Reply to this email directly, view it on GitHub, or unsubscribe.
onecarbon commented
Thanks! will try that way then