output U with surface value and use Uboudanry Tboudanry and rhoBoudanry as input
Opened this issue · 0 comments
zhulianhua commented
Sometimes, we need to output slip velocity and wall temperature, so it's better to use the standalone fields to assign boundary condition such as U and T. Just like the dsmcFoam.
That would require changing the setup of the case.