Wrong Parameters in DC BPT Parameter Set sent by SECC
AKKA-AntonioAlmeida opened this issue · 0 comments
AKKA-AntonioAlmeida commented
In state ServiceDetails, when executing an EV (following 15118-20 and using DC BPT) against your SECC, the ServiceDetailRes presents parameter sets with the wrong parameters.
The ServiceDetailRes sent is
{
"ServiceDetailRes": {
"Header": {
"SessionID": "594BDDEAA4B9B6D1",
"TimeStamp": 1724245420
},
"ResponseCode": "OK",
"ServiceID": 6,
"ServiceParameterList": {
"ParameterSet": [
{
"ParameterSetID": 1,
"Parameter": [
{
"Name": "Connector",
"intValue": 2
},
{
"Name": "EVSENominalVoltage",
"intValue": 400
},
{
"Name": "Pricing",
"intValue": 0
},
{
"Name": "ControlMode",
"intValue": 1
},
{
"Name": "MobilityNeedsMode",
"intValue": 1
}
]
},
{
"ParameterSetID": 2,
"Parameter": [
{
"Name": "Connector",
"intValue": 2
},
{
"Name": "EVSENominalVoltage",
"intValue": 400
},
{
"Name": "Pricing",
"intValue": 0
},
{
"Name": "ControlMode",
"intValue": 2
},
{
"Name": "MobilityNeedsMode",
"intValue": 2
}
]
},
{
"ParameterSetID": 3,
"Parameter": [
{
"Name": "Connector",
"intValue": 2
},
{
"Name": "EVSENominalVoltage",
"intValue": 400
},
{
"Name": "Pricing",
"intValue": 0
},
{
"Name": "ControlMode",
"intValue": 2
},
{
"Name": "MobilityNeedsMode",
"intValue": 1
}
]
},
]
}
}
}
when the expected list of parameters is
- Connector
- ControlMode
- MobilityMode
- Pricing
- BPTChannel
- GeneratorMode
If you could solve this as quickly as possible, we would be extremely grateful. Thank you in advance!