Dual Heater OpenTherm

(c) HomeAccessoryKid 2020-2021

TLDR

This repo is specific to my house, but you will find a reliable OpenTherm routine synchronized with DS18B20 temperature sensors and some whacky ideas how to heat a house like mine.

My House and the heating strategy

I live in a well isolated house with a stone bottom floor with floor heating. The top floor uses radiators in the rooms. All of this makes either the bottom too warm or the top too cold.

The Challenge

The heat-capacity of the bottom floor requires e.g. 5 hours of heating at 35 degrees to go up 1 degree. But overnight it only goes down by 1 degree. The outside temperature drives the amount of heat lost over time which drives the time needed which in the code is called factor for now. The intention is to make factor automatically adjusting, but not yet.
After having heated 5 hours, it takes one to two hours before things settle. So with three states - STABLE, HEAT and EVAL - I try to get the desired temperature without overshooting.

The top floor is much faster in reacting to heat input. And to make use of the modulation feature of the heater, I set the water temperature output as a linear function of the top floor setpoint minus measured temperature.

This is not a proper PID but I will fix that later. Maybe the fact that the kettle swithes off and on based on the fact(?) that it cannot get rid of the warmth when on the lowest modulation, is good enough.

The Catch

Finally, what to do if the bottom is warm enough and upstairs needs warming? The bottom floor is using a re-distribution construction with a helper pump. If the helper pump is off, the bottom hardly gets any heat, which is good enough for this plan.
The pump is controled by a SonoffBasic with a thermo sensor. Effectivly the pump only runs when there is heat input, saving a lot of electricity anyway. And because both the heater and the pump have HomeKit, I can inhibit the pump if needed.

HomeKit automation to bring it together

The heater will change and notify its current_heater_mode which, by using Eve, triggers a Scene that changes the pump active_state. The pump will change and notify its in_use value which, by using Eve, triggers a Scene that changes the target_heater_mode to cool. On these two events, the pump will stop for 3 minutes and the heater will know for sure this is true. The current values are set back to allow a new trigger to be detected.

The gory details

later... for now see the code

Version history

  • 0.8.1 change default settings to 19 degrees Celsius and ramp up time for heater2
  • 0.8.0 make heating countdown on active heater must be modulating to count down time
  • 0.7.9 initialise past tgt values and remove debug printing
  • 0.7.8 dynamic setpoint with booster make sure that booster setting dynamics do not get taken for new setpoint fix heat_mod logic debug printf to be removed later
  • 0.7.7 changed S3long and modulation reports S3long only reported at reset point heat_mod is curr_mod with overlay heat_mod is only reported if state is or was 0x0a and discarding 70%
  • 0.7.0 - 0.7.6 introducing MQTT updates to Domoticz an alert for ERR flag field many temperatures as well as modulation and pressure using base idx so, depends on consecutive block of idx (more or less)
  • 0.6.13 changed min temp value and pairing code in esp-homekit changed minimum from 0 deg celcius to -50 not starting UDPlogger and tasks until paired, else out of memory during pairing
  • 0.6.12 local debug version
  • 0.6.11 undo change to TEMPERATURE_SENSOR, .primary=true homekit started to ignore the device...
  • 0.6.10 also regulate heater2 at night just set the setpoint to a lower value
  • 0.6.9 automatic boost reset and remove outside water temperature sensors
  • 0.6.8 heat_sp fix brackets brackets brackets
  • 0.6.7 introduce S3long accumulated outside temperature and heat_sp as a float 8.8 and slow adjust for setpoint2 and more initialisation robustness
  • 0.6.6 prevent incorrect temperature readings and fix BLOR encoding error
  • 0.6.5 OT command testing for BLOR and Boiler Sequencer Control max modulation is controlled by tgt_temp2
  • 0.6.4 evaltime calculation and testing OT command support and some output formatting improvements
  • 0.6.3 some bizar leaking of values between tm and seven02 moving heater2 logic before heater1 and capture timestamp string before setting seven02
  • 0.6.2 weird stuff with the localtime function looks like it is a reference to the same object tm as before... probably 0.6.0 was OK after all except for this code issue
  • 0.6.1 re-issue of the 0.6.0 code to load fixed binary
    somehow the binary was compiled before the fix was saved (?)
  • 0.6.0 finally fixed the issue of heater2 on in the night
    because tm was abused, subsequent logic failed
    present heater on but pump off as cur_heat1=2 COOL
    initial README
  • 0.5.11 and before development cycle