usage

Power on: Recording data

Power off: Stop

realtime_time critical application

Timed_loop accuary is higher than while loop with both realtime delay and time dalay. (test coding is /timetest/RT_timing.vi)

Timed_loop maxium error: 100 us at 1250 us (loop time); 70 us at 1 s (loop time)