Middle man to recieve UART messages from Z80 computer and then open web-svr pdf viewer TASKS: • Handle Codes: All codes are transmitted in ASCII and are ended with a Carriage Return character (0A hex).
GENERAL CODES:
CI Coil Information, followed by the 13-digit coil number and the division the coil is for.
Sent on boot-up if there is an active coil.
Format: CI,nnnnnnnnnnnnn,n
Example: CI,0050123456789,1
NC New Coil, followed by the 13-digit coil number and the division the coil is for.
Sent when a new coil spec is downloaded or winding is started on a new coil.
Format: NC,nnnnnnnnnnnnn,n
Example: NC,0050123456789,3
NW New Winding, followed by winding type, material type, and conductor width.
Sent when a new winding is started.
Format: NW,XX,XX,nn.nnnn
where winding type is PA (Paper), LV (Low Voltage), or HV (High Voltage)
and material type is PM (Paper), WC (Wire), or SC (Sheet)
Example: NW,HV,WC,00.1250
RS Run Screen, followed by winding type, material type, and conductor width.
Sent when the operator changes to the Run Screen.
Format: RS,XX,XX,nn.nnnn
where winding type is PA (Paper), LV (Low Voltage), or HV (High Voltage)
and material type is PM (Paper), WC (Wire), or SC (Sheet)
Example: RS,LV,SC,08.2500
DE Data Entry screen. Sent when the operator changes to the winding data screen.
FC Finished Coil. Sent when a coil is completed.
“ALMOST” TURN STOPS:
AAD Almost at an Annular Duct stop
ACX Almost at a Crepe Extension Paper stop
ADS Almost at an End Duct stop
ALE Almost at a Layer End/End of Layer stop
APX Almost at a Plain Extension Paper stop
ATB Almost at a Tab Break/Section Break stop
ATS Almost at a Tap stop
ATT Almost at a Total Turns stop
AXP Almost at an Extra Paper stop
TURN STOPS:
AD Annular Duct stop
CX Crepe Extension Paper stop
DS End Duct stop
LE Layer End/End of Layer stop
PX Plain Extension Paper stop
TB Tab Break/Section Break stop
TS Tap stop
TT Total Turns stop
XP Extra Paper stop