Data read by getMagOnce() and getMagValue()

Closed this issue · 1 comments

getMagOnce(), which uses getMagValue(), only polls the registers for the real and imaginary data stored from a previous measurement and does not send a fresh "repeat frequency" or "increment frequency" command to acquire new data, right?

Yes. getMagOnce() just takes one magnitude data without sending a fresh "repeat frequency" or "increment frequency" command.