/gofaxip

GOfax.IP - T.38 / Fax Over IP backend for HylaFAX using FreeSWITCH

Primary LanguageGoGNU General Public License v2.0GPL-2.0

GOfax.IP

GOfax.IP is a HylaFAX backend/connector providing Fax over IP support for HylaFAX using FreeSWITCH and SpanDSP through FreeSWITCH's mod_spandsp.

In contrast to solutions like t38modem, iaxmodem and mod_spandsp's softmodem feature, GOfax.IP does not emulate fax modem devices but replaces HylaFAX's faxgetty and faxsend processes to communicate directly with FreeSWITCH using FreeSWITCH's Event Socket interface.

GOfax.IP is designed to provide a standalone fax server together with HylaFAX and a minimal FreeSWITCH setup; the necessary FreeSWITCH configuration is provided.

Features

  • SIP connectivity to PBXes, Media Gateways/SBCs and SIP Providers with or without registration
  • Failover using multiple gateways
  • Support for Fax over IP using T.38 and/or T.30 audio over G.711
  • Native SIP endpoint, no modem emulation
  • Support for an arbitrary number of lines (depending on the used hardware)
  • Extensive logging and reporting: Writing xferfaxlog for sent/received faxes; Writing session log files for all sent/received faxes
  • Support for modem status reporting/querying using HylaFAX native tools and clients: faxstat etc.
  • Call screening using HylaFAX' DynamicConfig

Components

GOfax.IP consists of two commands that replace their native HylaFAX conterparts

  • gofaxsend is used instead of HylaFAX' faxsend
  • gofaxd is used instead of HylaFAX' faxgetty. Only one instance of gofaxd is necessary regardless of the number of receiving channels.

Building

GOfax.IP is implemented in Go/golang. It was developed and tested with Go version 1.2.1. As Go binaries are (almost) statically linked, they can be built on any system and just placed on the target system.

Using Makefile

A simple Makefile is included that will set up GOPATH and embed the current HEAD's short commit hash into the version printed when running gofaxd -version or gofaxsend -version. Provided that the Go compiler is installed and the go command is executable, build by just typing make in the repository's root.

Building manually

Alternatively, GOfax.IP can be built manually using go:

export GOPATH=$(pwd)
go install gofaxd gofaxsend

The resulting binaries gofaxd and gofaxsend are located in the bin directory.

Installation

We recommend running GOfax.IP on Debian 8 ("Jessie"), so these instructions cover Debian in detail. Of course it is possible to install and use GOfax.IP on other Linux distributions and possibly other Unixes supported by golang, FreeSWITCH and HylaFAX.

Dependencies

The official FreeSWITCH Debian repository can be used to obtain and install all required FreeSWITCH packages.

Adding the repository:

echo 'deb http://files.freeswitch.org/repo/deb/debian/ jessie main' >> /etc/apt/sources.list.d/freeswitch.list
curl http://files.freeswitch.org/repo/deb/debian/freeswitch_archive_g0.pub | apt-key add -

Installing packages

apt-get update
apt-get install hylafax-server freeswitch freeswitch-mod-commands freeswitch-mod-dptools freeswitch-mod-event-socket freeswitch-mod-logfile freeswitch-mod-sofia freeswitch-mod-spandsp freeswitch-mod-timerfd freeswitch-mod-tone-stream freeswitch-mod-db freeswitch-sysvinit

It is recommended to run gofaxd using a process management system as it doesn't daemonize by itself. A configuration file for the supervisor process control system is provided in the GOfax.IP repository. To use it, the supervisor packae has to be installed:

sudo apt-get install supervisor
sudo cp config/supervisor/conf.d/gofaxd.conf /etc/supervisor/conf.d/

GOfax.IP

We do not provide packages (yet), so for now the two binaries have to be installed manually.

sudo cp bin/* /usr/local/sbin/

Configuration

FreeSWITCH

FreeSWITCH has to be able to place received faxes in HylaFAX' recvq spool. The simplest way to achieve this is to run FreeSWICH as the uucp user.

sudo chown -R uucp.uucp /var/log/freeswitch
sudo chown -R uucp.uucp /var/lib/freeswitch
sudo cp config/default/freeswitch /etc/default/

A very minimal FreeSWITCH configuration for GOfax.IP is provided in the repository.

sudo cp -r config/freeswitch /etc/freeswitch/

The SIP gateway to use has to be configured in /etc/freeswitch/gateways/default.xml. It is possible to configure multiple gateways for GOfax.IP.

You have to edit /etc/freeswitch/vars.xml and adapt the IP address FreeSWITCH should use for SIP/RTP.

GOfax.IP

Currently GOfax.IP does not use HylaFAX configuration files at all. All configuration for both gofaxd and gofaxsend is done in the INI-style configuration file /etc/gofax.conf. A sample config file is provided and has to be customized.

sudo cp config/gofax.conf /etc/

HylaFAX

To make HylaFAX use gofaxsend for sending, the SendFaxCmd option has to be added to /etc/hylafax/config:

SendFaxCmd:		"/usr/local/sbin/gofaxsend"

A sample FaxDispatch script is included in config/hylafax/FaxDispatch, the available CALLID values set by gofaxd are documented there.

To have faxstat show modem/channel usage in it's status output, a modem configuration file has to exist. Note that GOfax.IP currently does not use HylaFAX' modem configuration files, so they can be empty, but they have to exist for faxstat to show the modem.

If /etc/gofax.conf is configured to manage 5 (virtual) modems, you have to create the (empty) configuration files manually:

sudo touch /var/spool/hylafax/etc/config.freeswitch{0..4}

Operation

Starting

sudo /etc/init.d/freeswitch start
sudo /etc/init.d/supervisor restart
sudo /etc/init.d/hylafax restart

Logging

GOfax.IP logs everything it does to syslog.

Advanced Features

As the virtual modems visible in HylaFAX are not tied to preconfigured lines but assigned dynamically, it is not feasible to assign static telephone numbers to individual modems. Instead, GOfax.IP can query a DynamicConfig script before trying to send outgoing faxes that works similar to the DynamicConfig feature in HylaFAX' faxgetty. Using the sender's user id (owner), it can be used to set the Callerid, TSI and Header for each individual outgoing fax. It is also possible to reject an outgoing fax.

DynamicConfig for incoming faxes

DynamicConfig as used and documented in HylaFAX can be used by GOfax.IP. One option per line can be set, comments are note allowed.

Parameters The following arguments are provided to the DynamicConfig script for incoming faxes:

  • Used modem name
  • Caller-ID number
  • Caller-ID name
  • Destination number (SIP To-User)

Supported options

  • RejectCall: true will reject the call. Default is to allow the call
  • LocalIdentifier: +1 234 567 will assign a CSI (Called Station Identifier) that will be used for this fax reception. The Default CSI can be set in gofax.conf in the ident parameter.

DynamicConfig for outgoing faxes

This is a special feature of GOfax.IP, a similar mechanism does not exist in traditional HylaFAX installations.

Parameters The following arguments are provided to the DynamicConfig script for outgoing faxes:

  • Used modem name
  • Owner (User ID as set sendfax -o or the FAXUSER environment variable, optinally verified by PAM)
  • Destination number

Supported options

  • RejectCall: true will reject the outgoing fax. The fax will instantly fail and not be retried.
  • LocalIdentifier: +1 234 567 will assign a TSI (Transmitting Station Identifier) for this call. The Default TSI can be set in gofax.conf in the ident parameter.
  • TagLine: ACME will assign a header string to be shown on the top of each page. This does not support format strings as used by HylaFAX; if defined a header string is always shown with the current timestamp and page number as set by SpanDSP.
  • FAXNumber: 1337 will set the outgoing caller id number as used by FreeSWITCH when originating the call.

Fallback from T.38 to SpanDSP softmodem

In rare cases we noticed problems with certain remote stations that could not successfully negotiate with some T.38 Gateways we tested. In the case we observed, the remote tried to use T.4 1-D compression with ECM enabled. After disabling T.38 the fax was successfully received.

To work around this rare sort of problem and improve compatiblity, GOfax.IP can identify failed transmissions and dynamically disable T.38 for the affected remote station and have FreeSWITCH use SpanDSP's pure software fax implementation. The station is identified by caller id and saved in FreeSWITCH's mod_db. To enable this feature, set softmodemfallback = true in gofax.conf.

Note that this will only affect all subsequent calls from/to the remote station, assuming that the remote station will retry a failed fax. Entries in the fallback list are persistant and will not be expired by GOfax.IP. It is possible however to manually expire entries from mod_db. The used <realm>/<key>/<value> is fallback/<callerid>/<unix_timestamp>, with unix_timestamp being the time when the entry was added. See https://wiki.freeswitch.org/wiki/Mod_db for details on mod_db.

A transmission is regarded as failed and added to the fallback database if SpanDSP reports the transmission as not successful and one of the following conditions apply:

  • Negotiation has happened multiple times
  • Negotiation was successful but transmitted pages contain bad rows