SIM7070G AT+SHCONN problem
sweidling opened this issue · 1 comments
sweidling commented
Hi again,
I have noticed that after some time (3-4 weeks of operation) problems with AT+SHCONN (connection to web server via HTTPS) occur with the SIM7070G module. Other protocols like NTP will still work.
A reset via AT command or PWR_PIN does not solve the problem. The module must be disconnected from the power.
I have this problem with several modules. It doesn't seem to be an isolated case.
Has anyone else encountered this problem?
Thanks :)
Mark-Wills commented
Is it a problem with clock drift? Are you setting the time/date correctly
on the modem? I saw something about that a couple of weeks ago -
…On Fri, Dec 16, 2022 at 3:47 PM sweidling ***@***.***> wrote:
Hi again,
I have noticed that after some time (3-4 weeks of operation) problems with
AT+SHCONN (connection to web server via HTTPS) occur with the SIM7070G
module. Other protocols like NTP will still work.
A reset via AT command or PWR_PIN does not solve the problem. The module
must be disconnected from the power.
I have this problem with several modules. It doesn't seem to be an
isolated case.
Has anyone else encountered this problem?
Thanks :)
—
Reply to this email directly, view it on GitHub
<#320>, or
unsubscribe
<https://github.com/notifications/unsubscribe-auth/AFAGDCS5F2YCJPWNE6SUKJTWNSFJFANCNFSM6AAAAAATBEBEYI>
.
You are receiving this because you are subscribed to this thread.Message
ID: ***@***.***>